Aprilaire® Fresh Air Exchanger — Model 8100
Unit and Components
WARNING! 120 volts may cause serious injury from electrical shock. Discon- nect power supply before servicing.
CAUTION! Do not wash the EnergyMax® transfer core. It can be severely dam- aged.
|
|
|
| POWER |
|
| WASHABLE ALUMINUM |
| |
|
| BLOWER | CORD | |
ENERGYMAX® |
| FILTERS | 120 VAC | |
TRANSFER CORE |
|
| FAN ASSEMBLY |
|
|
|
| ||
|
|
|
| |
|
|
|
|
|
WARNING
LABELS
FRESH
AIR
TO
HOUSE
INSTR.
STALELABEL
AIR
TO
OUTSIDE
MAINTENANCE INSTRUCTIONS
1.Clean aluminum filters every six months and recoat with Super Filter Coat per directions on container. The filters are factory coated with RP Super Filter coat, which is available from your heating and air conditioning contractor. Super Filter Coat must be sprayed on the filter after each washing to maximize it’s efficiency.
2.Slide EnergyMax transfer core out annually by carefully pulling at the four corners. When it’s completely dry, gently vacuum the air passages with a soft brush attachment. Be careful not to damage the delicate surfaces and slide the energy transfer core back into housing pushing only at the four corners.
3.Check the fresh air intake (outside) vent every six months, and clean if necessary.
STALE AIR
FROM
HOUSE
FRESH AIR
FROM
OUTSIDE
4.Blower compartments should be inspected for debris buildup every six months, and cleaned if necessary. No maintenance is required for the blower motor.
Since Research Products Corporation does not sell equipment or service parts direct to consumers, please proceed as follows should you need anything:
•Call the installer of your Aprilaire® Fresh Air Exchanger. This information is often found on your equipment.
•Call your heating and air conditioning dealer.
•If none of the above is successful and you still need additional information, please feel free to write us.