APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO PAYNE

RELIANT AND ENDURA MODEL HEAT PUMP SYSTEMS

NOTE 1: W3 TERMINAL ON

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT

PAYNE PCB CAPPED

 

PAYNELOWVOLTAGETERMINALBOARD

R Y1 O B G E W2 L C Y2

24 VAC, RETURN

R

COMPRESSOR CONTACTOR

Y

REVERSING VALVE [COOLING MODE]

O

FAN CONTACTOR CIRCUIT

G

EMERGENCY HEATING CIRCUIT

E

2ND. STAGE HEATING CIRCUIT

W2

SYSTEM MONITOR LED

L

24 VAC, COMMON

C

3RD. STAGE HEATING CIRCUIT [CAPPED]

W3

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO RHEEM/RUUD

HEAT PUMP SYSTEMS

TERMVOLTAGE BOARDINAL

/RUUDLOWRHEEM

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT

R Y1 O B G E W2 L C Y2

24 VAC, RETURN

R

COMPRESSOR CONTACTOR

Y

REVERSING VALVE [HEATING MODE]

B

FAN CONTACTOR CIRCUIT

G

EMERGENCY HEATING CIRCUIT

E

2ND. STAGE HEATING CIRCUIT

W2

SYSTEM MONITOR LED

L

24 VAC, COMMON

X

B

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS