Aprilaire 8555 owner manual 110-793B 7/11/01 329 PM

Models: 8555

1 36
Download 36 pages 34.65 Kb
Page 23
Image 23

110-793B 7/11/01 3:29 PM Page 23

No. 2 – Smart Fan. The thermostat is factory preset with the Smart Fan option off. This allows the system fan to operate normally with the heating and cooling equipment. If the Smart Fan option is turned on by placing the DIP switch in the ON position when the Fan button on the thermostat is pushed (indicated by the fan icon on the display), the system fan will run continuously during the Morning, Day, and Evening events. During the Night event, the fan will automatically revert to cycling on and off with the heating and cooling equipment.

No. 3 – 4 Minute / 2 Minute Minimum Equipment On/Off Times. This switch is factory preset at 2 minutes. This switch provides short cycle protection for the heat pump. If you feel that the heat pump turns on and off too many times per hour, ask your contractor about changing the switch to a 4 minute minimum on time. Keep in mind, however, that this may increase the overall temperature variation in the house due to longer run and off times. Do not change the position of the switch without first consulting with your contractor.

No. 4 – Keypad Lock. If tampering with the thermostat is expected and unwanted, the keypad can be locked by moving this switch from the factory-preset OFF position to ON. This should not be done until all programming is finalized. In the locked position only the following functions can be done:

The outdoor temperature button will display the outdoor temperature.

– 21 –

Page 23
Image 23
Aprilaire 8555 owner manual 110-793B 7/11/01 329 PM