APW Wyott GGT-24H warranty GGT-36H, Lighting Instructions, Specifications

Models: GGT-24H

1 16
Download 16 pages 5.34 Kb
Page 6
Image 6
GGT-36H

GGT-36H

SPECIFICATIONS

 

 

 

Griddle Surface Dimensions

 

Width:

35

13/16”/910mm

 

Depth:

19

1/2”/496mm

4. LIGHTING INSTRUCTIONS

Lighting Instructions

GGT Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the European Community). Please follow the instructions for your unit.

Pilot Safety Valve Lighting Instructions

1Turn on main gas supply to unit, on-off valve located behind the unit (not supplied with unit).

2Turn the burner control knobs to "OFF" position. Open the front panel and wait at least 5 minutes to allow any gas which may have accumulated in the firebox compartment to escape.

3Depress red button on the pilot safety valve and light through observation hole in firebox. Keep red button on pilot safety depressed for at least 1 minute after pilot has lit. If pilot does not light, repeat this step.

4To adjust the pilot flame, rotate knob next to the red button. Turning the knob clockwise increases the pilot flame. A properly sized pilot should be 1/2" to 3/4" long (12/19 mm).

Standing Pilot Lighting Instructions ( Not Available in the European Community )

The pilot lights on the griddles have been set at the factory. A screwdriver maybe required for the first lighting to adjust the flame for your elevation.

1Turn off the manual shut off valve and wait 5 minutes to clear the gas.

2Turn all knobs to the "OFF" position.

3Remove the grease drawer and front panel for easy access.

4Turn the manual shut off valve on.

5Hold an ignition source (match) at the pilot tube. When the flame is established, remove the ignition

source.6

Page 6
Image 6
APW Wyott GGT-24H warranty GGT-36H, Specifications, Pilot Safety Valve Lighting Instructions