OPTION SPECIFICATIONS

 

Models

Drain

Drain

 

Wood Mt

Wood Mt

Description

w/Drains

Location

Couplings

Thermostat

Kit No’s

Kit Cut-Out

Full Size

HFW-1D

1 11/16” x 1 11/16”

½ NPT

72” (182.8)

56431

23 7/8” x 15 7/8”

(HFW-1)

 

(4.3 x 4.3) from

Stainless

Capillary

 

(60.6 x 40.3)

2/3 Size

HFW-23D

back right corner

1 1/2” (3.8)

Effective

56460

16 5/8” x 15 7/8”

 

long

Length

(HFW-23)

 

 

 

62” (157.5)

 

(42.2 x 40.3)

1/2 Size

HFW-12D

 

 

 

56413

13 5/8” x 15 7/8”

(HFW-12)

 

 

 

 

 

(34.6 x 40.3)

 

 

 

 

 

 

 

ELECTRICAL SPECIFICATIONS

Description

Rating at 120VAC, 1PH

Rating at 208VAC, 1PH

Rating at 208/240VAC, 1PH

HFW-1

1500 Watts, 12.5 Amps

1660 Watts, 7.7 Amps

1200/1600 Watts, 5.7/6.7 Amps

HFW-23

800 Watts, 6.7 Amps

HFW-12

800 Watts, 6.7 Amps

500/660 Watts, 2.4/2.8 Amps

INSTALLATION

Installation:

1.Follow applicable General Installation Instructions on page 2.

2.Make applicable Cut-Out per above table. CONNECTION NOTE: Unit is designed for installation in stainless steel tops. Optional wood mounting kit available.

3.Apply putty tape (Provided) to the underside perimeter of the well rim outer edge.

4.Apply a 1/4" (.6 cm) bead of silicone sealant adjacent to the putty tape on the well flange.

5.Drop well into opening from the top and push down until entire parameter of rim is flush with the counter surface.

6.From below the counter surface insert an 8" to 10" (20 cm to 25 cm) flat tip screwdriver into the locking ring tab slots and twist in a clockwise motion to lock well in place.

7.Trim excess putty and sealant from around well rim.

8.Mount control to front panel using hardware. Maintain 4" clearance between well and front panel. Connect power. Check power. Check nameplate for proper voltage. NOTE: Electrically connect unit in compliance with local and NEC codes.

4

Page 4
Image 4
APW Wyott HFW-1D, HFW-12D, HFW-23D Option Specifications, Electrical Specifications, Installation