ASSEMBLY INSTRUCTIONS FOR MOUNTING

LIQUID END TO MOTOR

STEP 1

Remove pump and motor from their boxes and check for any possible shipping damage.

STEP 2

Place motor vertically with shaft end up, being careful not to damage motor end bell. Remove shaft key on motor if installed.

STEP 3

Install liquid end to motor by placing the pump shaft onto the motor shaft and aligning the pump shaft set screws with the motor shaft keyway. Align pump bracket holes with threaded holes on motor and install four 3/8”-16 hexbolts and tighten with 9/16” wrench.

STEP 4

Place assembled pump in its normal position, on the pump base. To adjust impeller, place screwdriver on the pump shaft as shown, and gently pry pump shaft towards motor .015 inches and tighten one set screw with 1/8” Allen wrench. Rotate shaft to check if impeller is clear. If impeller is clear, tighten all set screws firmly. If impeller is not clear, loosen set screw and adjust impeller further until it rotates freely.

(See illustration above)

STEP 5

The pump is now ready for installation.