INSTALLATION & OPERATING INSTRUCTIONS

GENERAL

Your AQUA-FLO pump has been quality built and engineered to give maximum efficiency under normal water pumping conditions. Consult the manufacturer for any other applications.

LOCATION OF PUMP

For best pump performance, locate the system as close to the water source as possible. Provide adequate access around the pump for inspection and maintenance. Place pump on a firm level surface. Pump need not be bolted down unless required by local code.

PUMP CONNECTIONS

Suction line from pool (skimmer and main drain) must be connected to inlet at hair and lint trap. Discharge line to pool (return lines) must be connected to outlet at top of pump via filter. If pump is installed below water level of pool, install valves on the inlet and outlet piping to permit removing of equipment without draining the pool.

CAUTION: During the pressure test procedure, this pump is under pressure. DO NOT LOOSEN lock handles while pump is running or until all pressure is released. Tighten lock handles securely by hand only. Raise pressure slowly. Do not exceed 50 psi. Extreme care must be taken during pressure test. Failure to follow these instructions explicitly can result in personal injury.

PRIMING PUMP

At initial start-up, pump must be primed by filling hair and lint trap with water. To prime pump, remove cover from hair and lint trap: fill pump and suction trap with water. Replace cover (make sure the o-ring is in place) and tighten lock handles. Pump will now prime, with priming time depending upon lift and horizontal distance of suction piping.

CAUTION: Do not remove hair and lint strainer lid while pump is running or under pressure! Lid is held in place by lock handles which can be removed or tightened by hand. Basket must be kept clear of leaves and debris at all times.

REMOVING BASKET

1.) Turn off motor. 2.) Remove lid. 3.) Remove basket and empty debris. 4.)

Replace basket, fill with water, replace lid securely to prevent air from entering and tighten. DO NOT USE TOOLS. 5.) Turn on motor. 6.) Open air-relief valve on top of filter until steady stream of water comes out.

NOTE: If pump is installed below water level of pool, close return and suction lines prior to opening hair and lint pot. Make sure to re-open valves prior to operating.

DO NOT RUN PUMP DRY!

Always maintain proper water level in pool. If water level falls below skimmer intake, pump will suck air. Pump is equipped with a maintenance-free, heavy- duty mechanical seal. Damage will occur if pump runs dry, and warranty will be voided.

TO PREVENT FREEZING

Drain liquid from pump through plug at bottom section of volute. It is recommended to apply a good rust inhibitor into liquid end to prevent corrosion.