SECTION 5 - TROUBLESHOOTING
ERROR CODES
SYMPTOM | RULE OUT | RESOLUTION | |
|
|
| |
"FLO" |
|
| |
Insufficient water flow |
| Step 1: | |
through heater or | Insufficient Water Flow | Confirm water pump is on and water valves are in the correct position to allow | |
circulation pump is off |
| water to flow through Heat Pump. If error persists, proceed to next step. | |
| Filtration Dirty | Step 2: | |
| Confirm filtration system is clean. Backwash if needed. If error persists, | ||
|
| proceed to next step. | |
| Possible Water | Step 3: | |
| Pressure Switch | Request Service | |
“CEr” Error |
|
| |
Communication Fault | N/A | Request Service | |
“CSE” Error |
|
| |
Control System Error | N/A | Request Service | |
“dPC” Error |
|
| |
Defrost Sensor Shorted | N/A | Request Service | |
“dPO” Error |
|
| |
Defrost Sensor Open | N/A | Request Service | |
“FS” Error |
|
| |
Unit in defrost mode. | Normal defrost mode | Step 1: | |
| If error persists after air temperature is over 50° F, request service. | ||
|
| ||
“HP” Error |
|
| |
High Pressure. | Insufficient Water Flow | Step 1: | |
| Confirm water pump is on and water valves are in the correct position to allow | ||
|
| water to flow through Heat Pump. If error persists, proceed to next step. | |
|
| Step 2: | |
| Filtration Dirty | Confirm filtration system is clean. Backwash if needed. If error persists, | |
|
| proceed to next step. | |
| Possible Refrigerant | Step 3: | |
| Issue | Request Service | |
“HP5” Error |
|
| |
Equipment has | Insufficient Water Flow | Step 1: | |
registered high pressure | Follow steps outlined in “HP” error, then reset circuit breaker to clear error. If | ||
and/or Filtration Dirty | |||
five times and locked. | error persists, request service. | ||
| |||
“LP” Error |
|
| |
Refrigerant Issue | N/A | Request Service | |
“LP5” Error |
|
| |
Refrigerant Issue | N/A | Request Service | |
“OTA” |
|
| |
Over Temperature |
|
| |
Alarm | Other heating | Check if alternate heater (such as a solar heater) is heating water leading to | |
| heat pump. If “yes”, turn off alternate heater and check if error clears. If error | ||
| equipment | ||
Temperature over | persists, request service. | ||
| |||
110° F (Unit Locked) |
|
| |
“PC” Error |
|
| |
Water Temperature | N/A | Request Service | |
Sensor Shorted | |||
|
| ||
“PO” Error |
|
| |
Water Temperature | N/A | Request Service | |
Sensor Open | |||
|
|