! WARNING

Operating Instructions and Replacement Parts List

Installation (Continued)

NOTICE

An air leak in the

suction line may

 

prevent priming of the pump. Use of thread sealant is recommended.

Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating.

3.A check valve must be used in the suction line to maintain the self- priming capability. If no check valve is used the pump will need to be primed at the start of each operation. For best operation, the check valve should be installed at the intake of the suction line.(Figure 2).

Figure 2

4.A suction strainer is required to filter abrasive material.

5.The discharge hose and fitting should be leak-tight. A leak in the discharge hose will allow water to spray around the work site, making the site hazardous.

6.Keep all pipes and hose lines as short and straight as possible. Long lengths and curves in the pipes and hose lines will reduce the pressure the pump develops.

7.Fill the engine crankcase with oil. Refer to the engine operating manual for the specific grade of oil and amount required.

8.Fill the engine fuel tank with gasoline. Refer to the engine operating manual for specific gasoline type that is most efficient for this engine.

9.Add water to the priming port on the pump (See Figure 3). Continue adding water until the water level is approximately 3 inches from the top. Install the priming plug. The water in the pump will create the suction that primes the pump.

Priming

Port

Figure 3

10.Turn fuel valve to ‘ON’ position.

11.Move choke lever to ‘CHOKE’ position.

12.Move throttle lever to ‘START’ position.

13.Pull engine crank until engine starts. Once engine starts, move choke lever to ‘RUN’ position.

14.The pump will take several minutes to prime.

PIPING

Always place the pump as close as possible to the liquid being pumped. Keep all pipe and hose lines as short and straight as possible.

Support pump and piping when

assembling and after installation. Failure to do so may cause piping to break, pump to fail, etc; all of which can result in property damage and/or personal injury.

All suction connections must be airtight. If the pump won’t prime, check for leaks in the suction piping or fittings. If flexible suction hose is used instead of pipe, use reinforced hose with a two inch inner diameter. Non-reinforced flexible hose may collapse from the vacuum created as the pump primes.

Always use a strainer at the end of the suction pipe or hose. Position strainer so it doesn’t become clogged with stones or debris. A suction line check valve is

recommended.

Do not use this pump for suction lifts over twenty-five feet.

Maintenance

Always shut off the engine, allow the engine to cool, and remove the spark plug before performing any maintenance.

During freezing weather, open the drain port and allow all the water in the pump to drain. This will prevent damage to the pump when the water freezes. If the pump will be stored for a month or more, drain the water from the pump and follow the engine manufacturer’s recommendations for long-term storage.

The Honda engine is equipped with a low oil shut off sensor. The engine will shut down and will not restart if the oil level becomes low.

2

Page 2
Image 2
AquaPRO GPH550PRO operating instructions Maintenance, Piping

GPH550PRO specifications

The AquaPRO GPH550PRO is a state-of-the-art water pump designed for both residential and commercial use, offering unparalleled efficiency and reliability. With its robust construction and innovative features, it stands out as a top choice for those seeking an effective solution for water transfer, irrigation, and drainage.

One of the main features of the GPH550PRO is its impressive flow rate, capable of moving up to 550 gallons per hour. This high performance ensures that tasks such as filling pools, draining basements, or irrigating gardens are executed quickly and efficiently. The pump is powered by a durable and energy-efficient motor, ensuring that it can operate for extended periods without overheating or wearing out.

The AquaPRO GPH550PRO also incorporates cutting-edge technology that enhances its usability. For instance, it features a built-in thermal overload protection system, which automatically shuts down the pump if it begins to overheat. This not only prolongs the life of the pump but also ensures safety during operation. Its lightweight and portable design make it easy to transport, allowing users to quickly move it from one location to another as needed.

Durability is a key characteristic of the GPH550PRO. Constructed with corrosion-resistant materials, this pump is designed to withstand harsh environmental conditions, making it ideal for both indoor and outdoor applications. Additionally, the unit includes a removable suction filter that prevents debris from clogging the pump, ensuring consistent performance over time.

The AquaPRO GPH550PRO is also remarkably user-friendly. Its intuitive control panel allows for easy operation, while color-coded connections simplify the setup process. Equipped with a reliable power cord and high-quality hose fittings, the pump can be seamlessly integrated into existing systems without the need for complex installation.

In summary, the AquaPRO GPH550PRO is an outstanding water pump that combines high flow rates, advanced safety features, and durable construction. With its innovative technologies and user-friendly design, it is an ideal solution for a variety of water handling needs, ensuring optimal performance and longevity. Whether for home gardening, emergency drainage, or commercial applications, the GPH550PRO delivers exceptional results, proving to be a worthy addition to any toolkit.