Operating Instructions and Parts Manual
Troubleshooting Chart - All repairs must be completed by licensed or certified professionals.
Operating Instructions and Parts Manual | PRO1002403, PRO1502403, PRO2002403, | |
PRO100120, PRO150120, and PRO200120 | ||
| ||
|
|
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Symptom | Possible Cause(s) | Corrective Action(s) | Safety Alert | ||
Blower will not | 1. | Power Off | 1. | Check electrical connections and fuse | Disconnect power |
start |
|
|
| box / control panel | BEFORE taking any |
| 2. | Internal blower | 2. | Disconnect power then check for | corrective action(s) |
|
| overload trips |
| restrictions or blockage in air discharge |
|
|
|
|
| line |
|
| 3. | Brushes worn out | 3. | Replace motor |
|
| 4. | Nuisance trips | 4. | It is possible that if the blower is started |
|
|
|
|
| and stopped repeatedly in a short time |
|
|
|
|
| period, the thermal overload could |
|
|
|
|
| interrupt the circuit. Allow the unit to |
|
|
|
|
| cool and disconnect power. Restart after |
|
|
|
|
| 5 - 15 minutes (depending on warmth |
|
|
|
|
| of ambient conditions). |
|
|
|
|
|
|
|
Blower hums but | 1. | Rotor locked | 1. | Disconnect power then check for debris | Disconnect power |
will not run |
|
|
| or foreign object lodged in blower | BEFORE taking any |
|
|
|
| motor | corrective action(s) |
| 2. | Brushes worn out | 2. | Replace motor |
|
| 3. | Wrong voltage | 3. | Verify voltage is correct for blower |
|
|
|
|
|
|
|
Blower runs but | 1. | Low voltage | 1. | Check electrical connections | Disconnect power |
delivers little air |
|
|
| Verify voltage is correct for blower | BEFORE taking any |
| 2. | Blower too small for | 2. | Install additional blowers, or reduce | corrective action(s) |
|
| application |
| piping restrictions |
|
| 3. | Check valve installed | 3. |
| |
|
| incorrectly |
|
|
|
|
|
|
|
|
|
Internal blower | 1. | Blocked or restricted | 1. | Check for debris or foreign object | Disconnect power |
overload trips |
| air line |
| lodged in discharge line | BEFORE taking any |
| 2. | Check valve installed | 2. | corrective action(s) | |
|
| incorrectly |
|
|
|
|
|
|
|
|
|
Blower runs too | 1. | Incorrect line voltage | 1. | Check blower voltage requirements, | Disconnect power |
slow |
|
|
| make certain line voltage is correct | BEFORE taking any |
| 2. | Incorrect wire size | 2. | Verify correct wire gage is being used | corrective action(s) |
Description
The Air Blower is designed for outdoor spa applications. It is designed for low noise and a high air flow rate. The unit is UL listed and the motor is protected with a resetting thermal overload device. The blower is designed for permanent electrical connections.
The box contains the following:
•Blower
•Mounting Bracket
•UL Approved Check Valve
•Conduit Cover Plate, Gasket, and Screws
•Instruction Manual
Unpacking/Unit Inspection
After unpacking the blower, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.
DAMAGE TO THE UNIT DURING TRANSPORTATION IS NOT THE RESPONSIBILITY OF THE MANUFACTURER.
Important Safety Instructions
When installing and using this electrical equipment, basic safety precautions should always be followed.
READ AND FOLLOW ALL
INSTRUCTIONS.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols:
Danger indicates an imminently
hazardous situation which, if not avoided, will result in death or serious injury.
Warning indicates a potentially
hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a potentially
hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates important
information, that if not followed, may cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
This product or its power cord may
contain chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
GENERAL
To reduce the risk of injury, do not
allow children to use this product unless they are closely supervised at all times.
Install blower no less than 1 foot
(305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.
Blower is designed for outdoor use.
Install blower at least two feet above the ground in an area free of debris, chemicals, or sprinklers.
ELECTRICAL
Disconnect power before attempting to install, service, relocate or perform any maintenance. Tag and disconnect power and lock the fuse box / control panel to prevent unexpected application of power.
Risk of
Electric
Shock. Install blower at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing.
To reduce the risk
of electrical shock, connect the green colored wire inside the electrical box to the grounding terminal of your electrical service or supply with a continuous green insulated solid copper conductor minimum No. 8 AWG (8.4 mm2) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
SAVE THESE INSTRUCTIONS.
Installation
Guidelines
Failure to observe installation
guidelines, could result in death or serious injury.
See Figure 1 for recommended installation diagram.
1.Install at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.
2.The check valve supplied with the unit must be installed in a vertical orientation above the water level in an easily accessible location for serviceability. Take care to orient the check valve with the arrow pointing in the direction of the air flow inside the pipe.
3.Use a separate dedicated