Operating Instructions and Parts Manual

Troubleshooting Chart - All repairs must be completed by licensed or certified professionals.

Operating Instructions and Parts Manual

PRO1002403, PRO1502403, PRO2002403,

PRO100120, PRO150120, and PRO200120

 

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Symptom

Possible Cause(s)

Corrective Action(s)

Safety Alert

Blower will not

1.

Power Off

1.

Check electrical connections and fuse

Disconnect power

start

 

 

 

box / control panel

BEFORE taking any

 

2.

Internal blower

2.

Disconnect power then check for

corrective action(s)

 

 

overload trips

 

restrictions or blockage in air discharge

 

 

 

 

 

line

 

 

3.

Brushes worn out

3.

Replace motor

 

 

4.

Nuisance trips

4.

It is possible that if the blower is started

 

 

 

 

 

and stopped repeatedly in a short time

 

 

 

 

 

period, the thermal overload could

 

 

 

 

 

interrupt the circuit. Allow the unit to

 

 

 

 

 

cool and disconnect power. Restart after

 

 

 

 

 

5 - 15 minutes (depending on warmth

 

 

 

 

 

of ambient conditions).

 

 

 

 

 

 

 

Blower hums but

1.

Rotor locked

1.

Disconnect power then check for debris

Disconnect power

will not run

 

 

 

or foreign object lodged in blower

BEFORE taking any

 

 

 

 

motor

corrective action(s)

 

2.

Brushes worn out

2.

Replace motor

 

 

3.

Wrong voltage

3.

Verify voltage is correct for blower

 

 

 

 

 

 

 

Blower runs but

1.

Low voltage

1.

Check electrical connections

Disconnect power

delivers little air

 

 

 

Verify voltage is correct for blower

BEFORE taking any

 

2.

Blower too small for

2.

Install additional blowers, or reduce

corrective action(s)

 

 

application

 

piping restrictions

 

 

3.

Check valve installed

3.

Re-orient check valve

 

 

 

incorrectly

 

 

 

 

 

 

 

 

 

Internal blower

1.

Blocked or restricted

1.

Check for debris or foreign object

Disconnect power

overload trips

 

air line

 

lodged in discharge line

BEFORE taking any

 

2.

Check valve installed

2.

Re-orient check valve

corrective action(s)

 

 

incorrectly

 

 

 

 

 

 

 

 

 

Blower runs too

1.

Incorrect line voltage

1.

Check blower voltage requirements,

Disconnect power

slow

 

 

 

make certain line voltage is correct

BEFORE taking any

 

2.

Incorrect wire size

2.

Verify correct wire gage is being used

corrective action(s)

Description

The Air Blower is designed for outdoor spa applications. It is designed for low noise and a high air flow rate. The unit is UL listed and the motor is protected with a resetting thermal overload device. The blower is designed for permanent electrical connections.

The box contains the following:

Blower

Mounting Bracket

UL Approved Check Valve

Conduit Cover Plate, Gasket, and Screws

Instruction Manual

Unpacking/Unit Inspection

After unpacking the blower, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

DAMAGE TO THE UNIT DURING TRANSPORTATION IS NOT THE RESPONSIBILITY OF THE MANUFACTURER.

Important Safety Instructions

When installing and using this electrical equipment, basic safety precautions should always be followed.

READ AND FOLLOW ALL

INSTRUCTIONS.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols:

Danger indicates an imminently

hazardous situation which, if not avoided, will result in death or serious injury.

Warning indicates a potentially

hazardous situation which, if not avoided, COULD result in death or serious injury.

Caution indicates a potentially

hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates important

information, that if not followed, may cause damage to equipment.

General Safety

Information

CALIFORNIA PROPOSITION 65

This product or its power cord may

contain chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

GENERAL

To reduce the risk of injury, do not

allow children to use this product unless they are closely supervised at all times.

Install blower no less than 1 foot

(305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.

Blower is designed for outdoor use.

Install blower at least two feet above the ground in an area free of debris, chemicals, or sprinklers.

ELECTRICAL

Disconnect power before attempting to install, service, relocate or perform any maintenance. Tag and disconnect power and lock the fuse box / control panel to prevent unexpected application of power.

Risk of

Electric

Shock. Install blower at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing.

To reduce the risk

of electrical shock, connect the green colored wire inside the electrical box to the grounding terminal of your electrical service or supply with a continuous green insulated solid copper conductor minimum No. 8 AWG (8.4 mm2) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.

SAVE THESE INSTRUCTIONS.

Installation

Guidelines

Failure to observe installation

guidelines, could result in death or serious injury.

See Figure 1 for recommended installation diagram.

1.Install at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.

2.The check valve supplied with the unit must be installed in a vertical orientation above the water level in an easily accessible location for serviceability. Take care to orient the check valve with the arrow pointing in the direction of the air flow inside the pipe.

3.Use a separate dedicated 2-inch rigid PVC supply line from the blower to the spa.

877.278.2797

www.aquaprosystems.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

www.aquaprosystems.com

877.278.2797

4

1

Page 3
Image 3
AquaPRO PRO1502403 Description, Important Safety Instructions, General Safety Information, Installation Guidelines