AquaStar 170 VP manual Natural Gas, Liquid Propane, Minimum Vent Size* and Height, Water Pressure

Models: 170 VP

1 28
Download 28 pages 42.15 Kb
Page 27
Image 27
INSTALLATION CHECKLIST

INSTALLATION CHECKLIST

Gas Line Size*

Natural Gas

Nominal Iron Pipe Size*

1/2"

3/4"

1"

 

 

 

 

 

 

 

Model

80

25"

100'

150'

 

 

 

 

 

 

 

 

125

NR

40'

125'

 

 

 

 

 

 

 

 

170

NR

25'

80'

 

 

 

Liquid Propane

 

 

 

 

 

 

 

Semi-rigid Tubing

1/2"

5/8"

3/4"

7/8"

Model

80

15'

50'

100'

 

 

125

NR

20'

50'

100'

 

170

NR

NR

35'

70'

*Flex tubing greatly reduces capacity and, therefore, is not recommended.

Minimum Vent Size* and Height

Model

Min. Diameter

Min. Height

Alternative

 

 

 

 

80

4"

10'

6' with 5" vent

125

5"

10'

6' with 6" vent

 

 

 

 

170

6"

10'

6' with 7" vent

*WARNING: Vent size must not be restricted. Installation must comply with national and local codes.

Water Pressure

For installation on well systems, insure that your water pressure is between 30 - 50 psi.

27

Page 27
Image 27
AquaStar 170 VP manual Natural Gas, Liquid Propane, Minimum Vent Size* and Height, Water Pressure, Installation Checklist