AQ4 Installation instructions
2.7 Flow switch
Replacement piping and flow switch is included for 1600P/425PN and 1600H/425HN water heaters. Check your model number on the right side of the water heater cover to confirm which procedure to follow.
2.7.1 Models 1600P/425PN
1.Shut off cold water supply isolation valve. If none installed, install before proceeding. Open hot water tap to relieve water pressure if water is already connected.
2.Remove and save clip on lower right side of heat exchanger.
3.Using a flat head screw driver remove and save pin from front, right side of water valve. (Fig. 8)
4.Remove copper pipe and set aside.
5.Find and connect the black flow switch to the bushing and pipes shown in Fig. 9A. Secure together with supplied clips.
6.Position flow switch and connecting pipe and bushing in place of the copper pipe that was removed.
7.Reinstall pin in water valve and clip on heat exchanger connection.
8.Connnect the three prong Molex connector cable to the flow switch.
9.Connect control cable from vent motor to Molex connector cable with wire nuts as seen in
Fig. 10.
2.7.2 Models 1600H/425HN
1.Shut off cold water supply isolation valve. If none installed, install before proceeding. Open hot water tap to relieve water pressure if water is already connected.
2.Remove and save clip on lower right side of hydrogenerator.
3.Remove and save pin from front, right side of water valve using a flat head screwdriver.
(Fig. 8)
4.Remove copper pipe and set aside.
5.Find and connect the black flow switch to the pipes shown in Fig. 9B.
Note: There are two pipes included for connection from flow switch to
must use the longer pipe for this connection.
6.Position flow switch and connecting pipes in place of the copper pipe that was removed. Secure together with supplied clips.
7.Reinstall pin in water valve and clip on heat exchanger.
8.Connnect the three prong Molex connector cable to the flow switch.
9.Connect control cable to Molex connector cable with wire nuts as seen in Fig. 10.
Water valve pin
Pipe to heat exchanger
Fig. 8 Water valve pin
Connection to | Brass heat | |
exchanger | ||
water valve | ||
bushing | ||
|
Flow switch molex connector
Replacement pipe for pilot models
Fig. 9A 1600P/425PN flow switch connections
Connection to | Connection to |
hydro generator | water valve |
Replacement |
| |
pipes for hydro | Flow switch | |
models | ||
molex connector | ||
|
Fig. 9B 1600H/425HN flow switch connections
Connections from | Connection from |
Molex connector | vent motor (black |
cable (white and | and red) |
yellow) |
|
Fig. 10 Flow switch electrical connections
AQ4 Manual