6 720 608 030
Appliance details
3
2 Appliance details
2.1 GWH 1600 P specifications
(Technical data)
Approved in US/Canada
Capacity
GWH 1600 P: 4.3 GPM
Maximum output
GWH 1600 P: 91 525 Btu/hr
Maximum input
GWH 1600 P: 117 000 Btu/hr
Efficiency in %
Recovery efficiency 78%
Min. Output
GWH 1600 P: 23 906 Btu/hr
Gas Requirement
Gas connection (inches) - ¾” NPT
Inlet gas pressure under maximum operation*
Propane: 10.5” - 14” water column
Natural Gas: 5.7” - 14” water column.
* To measure Gas Pressure, see Measuring Gas
Pressure, chapter 3.8.
Venting
Natural Draft
Vent diameter (inches) - 5”
Minimum height (feet) - 6’ with no elbows
Vertical termination
Sidewall termination only with AQ4 power vent kit.
Water
Hot water connection (inches) - ½” NPT
Cold water connection (inches) - ½” NPT
Water valve mater ial: Polymer (PPS) (Polypropylene
Sulfid)
Minimum water flow: 0.5 gallon/minute (1.9 l/m)
Minimum recommended water pressure: 30 PSI
(2.07 bar)
• Connections:
Bottom of heater
Dimensions
Depth (in): 8.66” (220 mm)
Width (in): 18.11” (460 mm)
Height (in): 25.79” (655 mm)
Weight: 35 pounds (16 kg).
Gas types
Natural Gas.
LP Gas
Safety devices
Flame failure device (ionization thermocouple)
Pressure relief valve (supplied with heater)
Over heat prevention (temperature limiter).
Water resistant
IP X4.