CENTRAL HEATING

Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the following notes are given for general guidance.

PIPE WORK:

Copper tubing to BS EN 1057:1996 is recommended for water pipes. Jointing should be either with capillary soldered or compression fittings.

Where possible pipes should have a gradient to ensure air is carried naturally to air release points and water flows naturally to drain taps.

The appliance has a built-in automatic air release valve, however it should be ensured as far as possible that the appliance heat exchanger is not a natural collecting point for air.

Except where providing useful heat, pipes should be insulated to prevent heat loss and avoid freezing.

Particular attention should be paid to pipes passing through ventilated spaces in roofs and under floors.

BY-PASS:

The appliance includes an automatic by-pass valve, which protects the main heat exchanger in case of reduced or interrupted water circulation through the heating system, due to the closing of thermostatic valves or radiator valves within the system.

SYSTEM DESIGN:

This boiler is suitable only for sealed systems. Drain Cocks:

These must be located in accessible positions to permit the draining of the whole system and should be fitted at all low points. The taps must be at least 15mm nominal size and manufactured in accordance with BS 2870:1980.

SAFETY VALVE DISCHARGE:

The discharge should terminate facing downward on the exterior of the building in a position where discharging (possibly boiling water & steam) will not create danger or nuisance, but in an easily visible position, and not cause damage to electrical components and wiring.

The discharge must not be over an entrance or a window or any other type of public access.

AIR RELEASE POINTS:

These must be fitted at all high points where air naturally collects and must be sited to facilitate complete filling of the system.

The appliance has an integral sealed expansion vessel to accommodate the increase of water volume when the system is heated.

It can accept up to 6 litre (1.3 gal) of expansion water. If the heating circuit has an unusually high water content, calculate the total expansion and add an additional sealed expansion vessel with adequate capacity. This should be located on the return pipe work as close as possible to the pump inlet.

MAINS WATER FEED - CENTRAL HEATING:

There must be no direct connection to the mains water supply even through a non-return valve, without the approval of the Local Water Authority.

FILLING:

A temporary method for initially filling the system and replacing lost water during servicing and initial filling (in accordance with current Water Regulations), is provided as an integral part of the connection kit (see FIG. 2.4). The flexible hose must be removed once the system has been filled.

RESIDUAL HEAD OF THE BOILER

7

Page 7
Image 7
Ariston 41-116-04 installation instructions Residual Head of the Boiler

41-116-04 specifications

The Ariston 41-116-04 is a remarkable piece of technology that epitomizes modern design and performance in the home appliance sector. This innovative unit stands out for its blend of practicality and sophistication, making it a favorite among consumers seeking efficiency and elegance in their daily lives.

At the heart of the Ariston 41-116-04 lies its impressive energy efficiency. This appliance boasts an advanced A+ energy rating, ensuring minimal energy consumption while still delivering optimal performance. This not only contributes to lowering utility bills but also aligns with environmentally friendly practices, making it a responsible choice for eco-conscious consumers.

One of the key features of the Ariston 41-116-04 is its user-friendly interface. With intuitive controls and a clear digital display, users can easily navigate through various settings and options. This thoughtful design simplifies operation, allowing for a seamless experience whether you are a tech-savvy individual or someone who prefers straightforward functionality.

The versatility of the Ariston 41-116-04 is another considerable advantage. It offers multiple modes tailored for different cooking styles, ensuring that meals can be prepared to perfection regardless of the dish. Whether you need to bake, grill, or steam, this model provides an array of cooking options that cater to diverse culinary preferences.

The appliance also incorporates innovative technologies to enhance performance. For instance, the advanced heat distribution system ensures even cooking results, eliminating hotspots and guaranteeing uniformly cooked meals. The incorporation of high-quality materials in its construction offers durability and robust performance, an essential characteristic for any long-lasting appliance.

In terms of safety, the Ariston 41-116-04 is designed with multiple safety features, including an automatic shut-off and child lock functions. These elements provide peace of mind for families, knowing that safety is a priority in all operations.

In conclusion, the Ariston 41-116-04 is a stellar appliance that encompasses efficiency, user-friendliness, and advanced cooking technologies. With its emphasis on energy conservation and safety, it represents an excellent investment for any modern household looking to enhance their culinary experience while maintaining a commitment to sustainability.