B

IS THE

 

 

 

 

 

 

 

 

 

 

 

CHECK

P

 

0.5 mbar

1 - CHECK AIR PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH CABLE

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

2 - CHECK/REPLACE AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR PRESSURE SWITCH

 

 

 

P ON PRESSURE

 

 

 

 

 

 

 

 

 

PRESSURE SWITCH

 

ACTIVATED?

 

 

 

 

 

 

 

 

 

 

 

TEST POINT

 

 

 

 

 

 

 

3 - CHECK/REPLACE P.C.B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CBM2)

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P 0.5 mbar

1 - CHECK EXHAUST DISCHARGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 - CHECK VENTURI AND TUBES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 - CHECK THE FAN EFFICIENCY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 - REPLACE FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOES

 

 

 

 

 

 

 

 

 

 

 

1 - CHECK/REPLACE IGNITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE SPARK

 

NO

 

 

 

 

 

 

 

2 - CHECK THE CABLES

 

 

 

 

 

5 - CHECK/REPLACE P.C.B. (CBM2)

 

 

 

 

 

 

 

 

 

 

 

 

3 - CHECK SPARK GENERATOR

 

 

 

 

 

 

 

 

SEQUENCE

 

 

 

 

 

 

 

 

 

 

 

4 - CHECK IGNITION ELECTRODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - CHECK POWER SUPPLY TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IS THE BURNER

 

NO

 

 

 

 

 

 

 

THE GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 - CHECK OPERATION OF THE

 

 

 

 

 

4 - CHECK/REPLACE P.C.B. (CBM2)

 

 

 

 

 

ALIGHT?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 - REPLACE THE GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HAS THE

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILER SAFETY

 

PRESS THE RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTDOWN BEEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUTTON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACTIVATED?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - CHECK IF THE FLAME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STRIKES THE DETECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILER

 

 

 

 

 

ELECTRODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

2 - CHECK THE SOFT-LIGHT

 

 

4 - CHECK/REPLACE

 

 

 

 

 

 

 

 

 

WORKING?

GAS PRESSURE

 

 

P.C.B. (CBM2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 - CHECK/REPLACE DETECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

NORMAL

 

 

 

 

OPERATION

 

 

 

IS

1

FAULT LIST

 

POSSIBLE CAUSES

 

THERE STILL

NOISEY OPERATION

- MAIN HEAT EXCHANGER FAULTY OR BLOCKED

 

A PROBLEM?

YES

 

 

WITH LIME-SCALEDEPOSITS

 

 

 

 

 

 

 

-

LOW HEATING SYSTEM WATER PRESSURE

 

NO

 

 

- CHECK GAS PRESSURES

 

 

 

- CHECK HEATING THERMOSTAT

 

 

 

 

- CHECK FAN

 

 

 

 

- CHECK PUMP

 

NORMAL

2

DECREASE/INCREASE OF HEATING CIRCUIT

- CHECK FOR LEAKS ON THE HEATING CIRCUIT

 

 

PRESSURE

-

FAULTY FILLING LOOP

 

OPERATION

 

 

-

FAULTY EXPANSION VESSEL

 

 

 

 

 

 

3 REPEATED SHUTDOWNS

- FAULTY DETECTION ELECTRODES

 

 

 

 

- CHECK GAS PRESSURES

 

 

 

 

- CHECK FLAME DETECTION ELECTRICAL CIRCUIT

 

 

4

REPEATED OPERATION OF SAFETY THERMOSTAT

- FAULTY HEATING THERMOSTAT

 

 

 

 

- FAULTY OVERHEAT THERMOSTAT

 

 

 

 

-

PRESENCE OF AIR IN THE HEATING CIRCUIT

 

 

 

 

- CHECK BURNER PRESSURES

 

 

 

 

- CHECK EXCHANGER FLUEWAY

 

 

5 INSUFFICIENT RADIATOR TEMPERATURE

-

CHECK HEATING THERMOSTAT

 

 

 

 

-

CHECK BY-PASS

FC002Ac

 

 

 

- CHECK GAS PRESSURE

 

 

 

 

18

B063

Page 38
Image 38