The boiler is protected from malfunctioning by means of internal checks performed by the electronic microprocessor P.C.B., which stops the boiler from operating if necessary.

In the event of the boiler being shut off in this manner, the LED shows the type of shut-off and the reason behind it.

There are two types of shut-off:

Safety shut-off

This type of error is “volatile”, which means that the boiler starts up

Cagain automatically as soon as the problem which caused the shut-off

is removed; the yellow LED 9 flashes and the C.H. temperature LED 1 indicate the error code. (see table)

As soon as the cause of the shut-off disappears, the boiler starts up

Bagain and continues to operate normally.

If the boiler still indicates a safety shut-off , switch it off. Make sure the external electric switch is in the OFF position and contact a qualified technician.

1. General layout

The mechanical clock covers a 24 hour period. Each tappet repre- sents 15 minutes A. An override switch is located on the clock B.

2. To set the time

To set the time of day, grasp the outer edge of the dial and turn slow- ly clockwise until the correct time is lined up with the arrow C.

3. To Set the “On” and “Off” times

The clock uses a 24hours system. e.g. 8 = 8.00 am and 18 = 6.00 pm “ON” periods are set by sliding all tappets between the “ON” time and the “OFF” time to the outer edge of the dial.The tappets remaining at the centre of the dial are the “OFF” periods.

4. For operation

Put the selector switch B to the symbol to control the central heating by the clock. Put the switch B to “I

to select permanent operation or to “0” to turn the central heating off permanently.

Shutdown due to insufficient water circulation

If the green leds 1 flash and the boiler is off , one possible cause for this state is an insufficient pressure of water in the system - green LED 40- 50 blink. Check the water pressure on the pressure gauge 4 and make sure that is between

0.6 and 1.5 bar when

 

 

 

 

 

 

 

 

the system is cold. If

 

 

 

 

 

 

 

 

the pressure is

just

 

 

 

 

 

 

 

 

 

 

 

 

under

the

minimum

 

 

 

 

refill

the

system by

 

 

 

 

opening

the

valve

 

 

 

 

under the boiler.

 

 

 

 

 

If the pressure drops

 

 

 

 

very frequently, there

 

 

 

 

may be a water leak

 

 

 

 

at some point in the

Note: Connections viewed from behind boiler

system. If this is the

 

 

 

 

case a plumber should be contacted.

Operation shutdown

This type of error is “non-volatile”, which means that it is not removed automatically (the red LED 8 will illuminate and the C.H. temperature LED 1 will indicate the error code). In this case the boiler does not restart automatically, but it may be reset by pressing the button. If the problem manifests itself again after several attempts to reset the appliance, contact a qualified technician.

Important

If this shutdown occurs frequently, contact an authorised service centre for assistance. For safety reasons, the boiler will allow a maximum of 5 reset operations to take place in 15 minutes (individual presses of the button). If the shutdown is occasional or an isolated event, this is not a problem.

6

Page 6
Image 6
Ariston 41 - 116 - 34 manual Clock Instructions E-COMBI Boiler protection devices, Safety shut-off, Operation shutdown

47 - 116 - 63, 41 - 116 - 34, 41 - 116 - 35, 47 - 116 - 62, 47 - 116 - 64 specifications

Ariston is a well-known brand in the realm of heating solutions, with products designed to meet diverse needs for comfort and efficiency. Among its notable offerings are the models Ariston 47 - 116 - 64, 47 - 116 - 62, 41 - 116 - 35, 41 - 116 - 34, and 47 - 116 - 63. Each of these models is engineered with specific features that cater to varying demands in heating systems, making Ariston a trusted choice for consumers looking for reliability and performance.

The Ariston 47 - 116 - 64 is characterized by its high-efficiency heat exchange technology, which ensures optimal energy use, translating to lower utility bills. Combining this with advanced control systems allows users to fine-tune temperature settings for maximum comfort. It features a sleek design, making it suitable for modern homes, and its compact nature allows for easy installation in limited spaces.

Similarly, the 47 - 116 - 62 model emphasizes user-friendly controls with intuitive interfaces to simplify operation. This unit is also engineered with robust materials that enhance durability, ensuring years of reliable service. Its energy-saving rating is particularly appealing for environmentally-conscious consumers, as it contributes to reduced carbon footprints.

The Ariston 41 - 116 - 35 model supports advanced connectivity options, enabling users to control their heating systems remotely via smartphone applications. This feature not only adds convenience but also allows for better energy management. The model is built to cope with varying load demands, making it adaptable for residential or commercial settings.

In addition, the 41 - 116 - 34 is praised for its silent operation, catering to those who prioritize tranquility in their living environments. It incorporates cutting-edge noise reduction technology, making it ideal for bedrooms or study areas.

Finally, the Ariston 47 - 116 - 63 rounds out this series with its powerful heating capability. Designed to heat larger spaces efficiently, it maintains consistent temperatures across various rooms, providing comprehensive coverage.

Overall, each Ariston model boasts distinctive features, state-of-the-art technologies, and excellent performance characteristics, ensuring comfort and efficiency in diverse applications. Whether for a home, office, or commercial space, the Ariston series meets the demands of modern heating needs while prioritizing sustainability and user control.