In calculating the lengths of the pipes, the maximum length must also take into consideration the values for the exhaust/air intake end terminals, as well as 90° elbows for coaxial systems.

The C52 types must comply with the following requirements:

1.The discharge/intake vent pipes must have the same diameter of ø 80 mm.

2.The maximum combined flue length is 17 m for Models Genus 23/27 MFFI/RFFI and 15 m for Model Genus 30 MFFI. In this case the minimum length for the air intake pipe is 1 meter; the maximum length of ver tical exhaust pipe must be a maximum of 12 m.

3.If an elbow is inserted into the discharge/ventilation system, the calculation of the overall extension must take into consideration the values for each curve, as indicated in the table.

4.The exhaust pipe must extend at least 0.5 m above the ridge of the roof if it is located on a side other than that for the air intake (this is not obligatory if the exhaust and air intake pipes are located on the same side of the building).

(*) L = Length of Piping

 

 

Twin Pipe Systems

 

 

Systems

Coaxial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C52 (xy)

C42 (xy)

C32 (xy)

C12 (xy)

 

C42 (xx)

C32 (xx)

C12 (xx)

 

 

 

Exhaust Type

 

 

 

 

 

 

 

 

 

 

 

 

 

17 m

54 m

54 m

54 m

23 kW

4 m

4 m

4 m

23 kW - 27 kW

 

Exhaust/Air

Maximum Extension

17 m

46 m

46 m

46 m

27 kW

15 m

50 m

50 m

50 m

30 kW

3 m

3 m

3 m

30kW

 

 

 

 

 

 

 

 

 

 

 

 

 

ø 80

ø 80

ø 80

ø 80

 

ø 60/100

ø 60/100

ø 60/100

(mm)

Pipes

Diameter

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

L < 7 m

L < 7 m

L < 7 m

L < 7 m

 

L * < 0.5 m

L * < 0.5 m

L * < 0.5 m

23kW

42 mm

Use of Restrictor

L <

L <

L <

L <

 

L * <

L * <

L * <

27

5 m

5 m

5 m

5 m

 

0.5 m

0.5 m

0.5 m

kW

 

 

on Discharge Side

L < 7.5 m

L < 7.5 m

L < 7.5 m

L < 7.5 m

 

L * < 0.5 m

L * < 0.5 m

L * < 0.5 m

30 kW

45 mm

 

 

 

 

 

 

 

 

 

 

 

 

L > 4.9 m

L > 4.9 m

L > 4.9 m

L > 4.9 m

 

 

 

 

23kW

 

 

Risk of Condensation

L < 5.3 m

L > 6.5 m

L > 6.5 m

L > 6.5 m

 

 

 

 

27 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L > 4.5 m

L > 4.5 m

L > 4.5 m

L > 4.5 m

 

 

 

 

30 kW

 

 

Forming

 

 

 

 

 

 

 

 

 

 

 

 

 

14

B004

Page 14
Image 14
Ariston 47-116-08. 47-116-09, 47-116-13, 41-116-01 installation instructions KW 27 kW Exhaust/Air Maximum Extension