Ariston HBK 9 LS X manual Controls

Models: HBK 9 LS X

1 13
Download 13 pages 4.81 Kb
Page 11
Image 11
CONTROLS

CONTROLS

To select the functions of the hood just touch the commands.

T1. ON/OFF Lights

T2. Speed decrease

Press key "T2" to decrease the speed from 4 (intensive) to 1.

Press key "T2" during operation at speed 1, the hood moves to OFF state.

T3. Speed increase

Press button T3 and the hood moves to OFF state at speed 1.

Press the button (hood in ON state) to increase the motor speed from 1 to the intensive speed (timed).

Speed 1 LED L1 Speed 2 LED L1+L2 Speed 3 LED L1+L2+L3

Intensive speed (timed) LED L1+L2+L3+L4 flashing

Note: Speed 4 (intensive timed) keeps on for 5 minutes, after that the hood sets speed 2 automatically

T4. Speed timing / Filter saturation signal control and configuration Speed timing:

The speed timing is activated by pressing key T4, when the timing has elapsed the hood switches off.

The timing is divided as follows:

Speed 1 - 20 minutes (LED L1 flashing) Speed 2 - 15 minutes (LED L1+L2 flashing) Speed 3 - 10 minutes (LED L1+L2+L3 flashing)

Intensive Speed - 5 minutes (LED L1+L2+L3+L4 flashing)

During the timed operation, press key T2 and the hood quits the timed mode and decreases the speed.

Press key T3 and the hood quits the timed mode and increases the speed. Press key T4 and the hood quits the timed mode keeping the speed set.

Filter saturation signal control and configuration

Grease filter signal

After 80 working hours LED L1 flashes.

When such signal appears, carry out the maintenance of the grease filter.

To reset the signal: with hood on, keep key T4 pressed for 5”.

The hood gives out a "BEEP" and then it switches off; LED L1 stops flashing.

Charcoal filter signal

After 320 working hours LED L2 flashes.

When such signal appears, carry out the maintenance of the charcoal filter.

To reset the signal: with hood on, keep key T4 pressed for 5”.

The hood gives out a "BEEP" and then it switches off; LED L2 stops flashing.

In the case of contemporaneous signaling of both filters, LEDs L1 and L2 flash.

The signal is reset by carrying out the procedure described above 2 times. The first time it resets the charcoal filter signal, the second time it resets the grease filter signal.

Note: In the standard mode the charcoal filter signal is not active.

When the hood is used in filter version, activate the charcoal filter signal.

Activating charcoal filter signal:

Set the hood to OFF and keep key "T4" pressed for 5”.

As soon as the key is pressed, the relevant LEDs of the signals of the filters currently active will light up. Keep pressing, the hood will give out a "BEEP" and LED L2 will flash for 2".

LEDs L1 and L2 remain on for about 2" before the hood gets back to OFF state.

Deactivating charcoal filter signal:

Set the hood to OFF and keep key "T4" pressed for 5”.

As soon as the key is pressed, the relevant LEDs of the signals of the filters currently active will light up. Keep pressing, the hood will give out a "BEEP" and LED L2 will switch off.

LED L1 remains on for about 2" before the hood gets back to OFF state.

T5. Sensor control key (ON-Automatic mode / OFF-Manual mode): Automatic operating mode (COOKING)

The system is set by default to the "manual operating mode", to activate the "automatic operating mode" press key "T5".

With hood off: LEDs L1+L4 switch on

With hood on: the LED of the speed selected switches on while the other LEDs start flashing.

During cooking, the system promptly reacts to Vapour/Gas increases: it switches the hood on at the most suitable speed and keeps working at the same speed for at least 1 minute, before getting back to the lowest speed/switching off.

When cooking is over and the environmental parameters are back on the levels prior to cooking the system switches off.

Note: If the parameters are close to the rest condition the system forces the hood switching-off after 30 minutes.

It is possible to deactivate the " automatic operating mode" as follows:

-Press key "T5" and the motor gets back to the "manual operating mode".

Note: it is also possible to get back to the manual operating mode by

pressing keys "T2", "T3" or "T6", the system decreases ("T2"), increases ("T3") the motor speed or switches ("T6") the hood off.

T6. ON/OFF Suction motor: With hood on at any speed, press key "T6" and the hood switches off.

With hood off, press key "T6" and the hood switches on at Speed 1.

Selection of the hob

This operation is necessary to optimize the automatic functioning of the hood, according to the type of hob selected.

Note: The hob set by default is the Gas hob.

To select a different hob (or to check the hob set) follow the instructions below: Set the hood to OFF

Press keys "T2" and "T3" contemporaneously for about 5 seconds until the hob being used is displayed (the hood gives out a "BEEP" signal).

Gas hob: LED "L1" on

Induction hob: LED "L2" on

Electric hob: LED "L3" on

The cyclical selection of the hob is possible by pressing keys "T2" or "T3". Once the hob has been selected, wait for 10” to accept the function.

The acceptance of the hob selected is displayed by the sequence of 3 flashes of the relevant LED of the hob selected.

After selecting the hob it is necessary to carry out the "Sensor calibration" again.

Sensor calibration (Automatic or Manual)

In order that the sensor responds correctly to the thermal stresses produced by the hob below it is necessary to calibrate the sensor.

Note: before calibrating the sensor carry out the "Selection of the hob", see previous paragraph.

Note: Carry out the calibration when installing the hood for the first time, after a long period of non-use or a blackout.

The calibration must be carried out with motor off.

Automatic calibration of the sensor

The automatic calibration of the sensor starts as soon as the hood is fed (visible by pressing key T5), LEDs L1+L4 flash for a period of time that can vary according to the hob selected, however no longer than fifteen minutes

Manual calibration of the sensor

Note: Carry out the manual calibration after a long period of non-use, after a blackout or when there is a very quick change in temperature in the kitchen

The calibration can be carried out manually: Set the hood to OFF

When keys "T6" and "T5" are pressed contemporaneously for 5", LEDs "L1" and "L4" start flashing for a period of time that can vary according to the hob selected, however no longer than fifteen minutes

EN

15

Page 11
Image 11
Ariston HBK 9 LS X manual Controls