Installation
Continued
CAUTION: Due to high tem- peratures, make sure wires are not touching upper firebox.
Glass
Locating
Holes
Recommended
Blower Speed
Control
Location
Spring Latch
Figure 33 - Removing Louver
Electrical Hookup for optional blower accessory
Before blower accessory can be operated, the ap- pliance outlet box must be properly connected to a standard 120 VAC power source. This must be done when the appliance is originally installed. Refer to Wiring Diagrams on page 31.
An outlet box with two receptacles has been sup- plied for your convenience and is located on the lower right side of the appliance (see Figure 34). The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance behind the louvered opening (see Figure 33).
You may test the blower for operation by turning the control knob clockwise just until it clicks on which is the full on position. Adjust the fan speed to the lowest setting (this should be no more than 1/4 of a turn clockwise).
For Optional
Fan Kit
From Blower
Assembly
Figure 34 - Connecting Blower
Accessory to Power Supply
OPTIONAL Wireless
Note: If using an optional wireless
NOTICE: Only use alkaline bat- teries (not included).
Installing HRC100 Model Remote Control (Millivolt Models Only)
1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 18).
2.Disconnect wall switch wires from termi- nals marked TH and TPTH (see Figure 32, page 18).
3.Slide
4.Connect white wire to control valve terminal TH and red wire to TPTH. Move remote select switch to REMOTE position.
5.Replace louvered access panel by following reverse of step 1 under Wall Switch Installa- tion, page 18.
6.Remove battery cover on back of
7.Attach terminal wires to
8.Replace battery cover onto
9.Set selector switch on receiver to OFF posi- tion if you will be away from the unit for an extended period of time.
Plastic Mounting Clips
Gas Receiver Clip
Valve Terminal
Wires
|
| LOT |
|
O N |
| 16AI |
|
OT |
| 7 | TH |
L |
| ||
I |
|
|
|
P |
|
|
|
FFO | L |
| TP |
| O | HI | |
E | A |
| TPTH |
|
|
Red | White | |
FRONT | ||
To Thermopile | ||
|
Figure 35 - Installing Remote Receiver
(HRC100)