OPERATING FIREPLACE

Continued

5.Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 27. If you don’t smell gas, go to the next step.

6.Turn main burner wall switch to the ON position for ignition. There will be a spark at the electrode. The electrode is located by the main burner.

7.Replace control access panel or louver once there is a flame at the burner.

If burner will not stay lit after several tries, flip wall switch to OFF and call your service technician or gas supplier.

Models (V)DVF36TCRP(E) and

(V)DVF36TCLP(E)

• Input Rating: 31,000/20,000 Btu/Hr

• Fuel: Propane/LP Gas

• Manifold Pressure: 10.0" W.C.

• Minimum Supply Pressure: 11.0 W.C. **

• Maximum Supply Pressure: 13.0" W.C.

• Orifice Size (0-4500 ft.): #51 DMS **For purpose of input adjustment.

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so,

From Gas

 

 

Supply

 

 

 

 

L

 

 

O

 

E

A

Inlet

Outlet

Pressure

 

Pressure

I H

O

 

PIL T

To

 

 

Main

 

Burner

When Gas Pressure Is Too Low Flame

Adjustment

Knob

contact your local gas supplier.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers ready.

Figure 58 - Electronic Control Valve
Figure 59 - Electrode

TO TURN OFF GAS

TO APPLIANCE

1.Turn off all electrical power to appliance if service is to be performed.

2.Remove control access panel or louver.

3.Close gas valve.

Specifications

Models (V)DVF36TCR(E) and

(V)DVF36TCL(E)

• Input Rating: 35,000/23,300 Btu/Hr

• Fuel: Natural Gas

• Manifold Pressure: 3.5" W.C.

• Minimum Supply Pressure: 4.5 W.C. **

• Maximum Supply Pressure: 10.5" W.C.

• Orifice Size (0-4500 ft.): #34 DMS

You can also visit DESA’s Technical Services web site at www.desatech.com.

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA’s Technical Service Department at 1-866-672-6040 for referral information.

When calling DESA, have ready

• your name • your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

28

www.desatech.com

112108-01C

Page 28
Image 28
Desa (V)DVF36TCLP(E) Continued, To Turn Off Gas To Appliance, Parts Under Warranty, Parts Not Under Warranty, Electrode