OPERATING FIREPLACE
Continued
5.Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 27. If you don’t smell gas, go to the next step.
6.Turn main burner wall switch to the ON position for ignition. There will be a spark at the electrode. The electrode is located by the main burner.
7.Replace control access panel or louver once there is a flame at the burner.
•If burner will not stay lit after several tries, flip wall switch to OFF and call your service technician or gas supplier.
Models (V)DVF36TCRP(E) and
(V)DVF36TCLP(E)
• Input Rating: 31,000/20,000 Btu/Hr
• Fuel: Propane/LP Gas
• Manifold Pressure: 10.0" W.C.
• Minimum Supply Pressure: 11.0 W.C. **
• Maximum Supply Pressure: 13.0" W.C.
• Orifice Size
Service Hints
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so,
From Gas |
|
|
Supply |
|
|
|
| L |
|
| O |
| E | A |
Inlet | Outlet | |
Pressure | ||
| Pressure |
I H
O |
|
PIL T | To |
| |
| Main |
| Burner |
Flame
Adjustment
Knob
contact your local gas supplier.
Technical Service
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Technical Service Department at
Figure 58 - Electronic Control Valve
Figure 59 - Electrode
TO TURN OFF GAS
TO APPLIANCE
1.Turn off all electrical power to appliance if service is to be performed.
2.Remove control access panel or louver.
3.Close gas valve.
Specifications
Models (V)DVF36TCR(E) and
(V)DVF36TCL(E)
• Input Rating: 35,000/23,300 Btu/Hr
• Fuel: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size
You can also visit DESA’s Technical Services web site at www.desatech.com.
Replacement Parts
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA’s Technical Service Department at
When calling DESA, have ready
• your name • your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA at
When calling DESA, have ready
•model number of your fireplace
•the replacement part number
28 | www.desatech.com |