Desa (V)DVF36TCRP(E), (V)DVF36TCLP(E) Burner Flame Adjustment, Cleaning and Maintenance

Models: DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP (V)DVF36TCRP(E) (V)DVF36TCLP(E)

1 36
Download 36 pages 42.35 Kb
Page 25
Image 25
Cleaning and

Burner Flame

Adjustment

Continued

5.To reinstall burner, follow reverse steps making sure air shutter on burner tube is completely seated over orifice mount.

6.Replace log set. Close door and latch. Reattach screen and louvers.

Manual background CAUTION: Make certain ori- fice is fully inside venturi tube's air shutter and that air shutter is adjusted accordingly, see Figure 50, page 24.

Cleaning and

Maintenance

When lit for the first time, the appliance may emit a slight odor for about 16 - 24 hours. This is normal and is due to the “curing” of the logs and the “burn-in” of internal paints and lubricants used in the manufactur- ing process. Keep compartments, logs, burners, and area surrounding the logs clean by vacuuming or brushing at least twice a year. Temporary removal of the log set may ease the cleaning of the burner and pilot assembly. In cleaning, take care not to alter the pilot or burner location. Be sure appliance is cool before each maintenance session.

Manual background CAUTION: The appliance and logs can get very hot. Handle only when cool.

Manual background WARNING: Turn off gas and wall switch before servicing appliance. Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.

Manual background WARNING: Make certain wires and gas lines are not touching the underside of the firebox.

Manual background WARNING: Make certain that wires and gas lines are not touching underside of firebox.

Manual background WARNING: Children and adults should be alerted to the hazards of high surface tem- peratures, and to stay away from the appliance to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.

Manual background WARNING: Have a qualified agency periodically inspect the vent system at the start of each heating season, for any obstruc- tion which may hinder its normal operation. Never obstruct the flow of combustion and venti- lation air. Keep the front of the appliance clear of all obstacles and materials.

Manual background Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and danger- ous operation.

Cleaning and Replacing

Glass Door

Note: Before proceeding, make sure unit is com- pletely cool.

1.Remove top and bottom louvers and screen assembly. Undo 4 latches and open glass door. The procedure is the same for the end louver panel but the entire frame must be removed as one assembly.

2.To clean glass door, DO NOT remove glass from frame. Use any glass cleaner to clean glass. Do not use abrasive cleaners as this may damage glass.

112108-01C

www.desatech.com

25

Page 25
Image 25
Desa (V)DVF36TCRP(E), (V)DVF36TCLP(E) installation manual Burner Flame Adjustment, Cleaning and Maintenance