Desa (V)DVF36TCRP(E), (V)DVF36TCLP(E) Continued, High altitude installation, Vertical Venting

Models: DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP (V)DVF36TCRP(E) (V)DVF36TCLP(E)

1 36
Download 36 pages 42.35 Kb
Page 17
Image 17
Vertical Venting

Venting Installation

Instructions

Continued

Vertical Venting

V = 40' max.

45° Starter

Elbow

Note: Install restrictor into inner collar of fireplace as shown.

Figure 29 - Vertical Rigid Venting

Configuration With No Horizontal Run

High altitude installation

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2,000 feet and certified for elevations from 0-5,000 feet.

Fireplaces for High Altitude (models ending in HA) are for installation above 4,000 feet only. These fireplaces are equipped with parts specific for higher altitudes. IMPORTANT: These fire- places can NOT be converted to propane/LP gas. When installing a non-high altitude fireplace at an elevation above 2,000 feet (USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1,000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4,500 feet (Canada), check with local authorities.

Consult with your local gas company to help de- termine the proper orifice size and identification for your location.

Components and parts must be ordered by part number through your local dealer or distributor.

IMPORTANT: For horizontal installations above 2,000 feet, it is recommened that a 12" extension pipe be added before starter elbow (see Figure 30).

45° Starter

Figure 29 - Vertical Rigid VentingConfiguration With No Horizontal RunElbow

12" High altitude installation Extension

Figure 30 - Recommended 12" Extension

for High Altitude Installation

parts list for DESA venting kits and components

DESA (5"/8") Pipe & Vent Kits

Number Description

VKR-58 Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Flue Restrictor, Vertical High Wind Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm Collar, Roof Flashing [0/12 - 6/12], 26 Screws)

VKB-58 Basement Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 4' Pipe, 90° Elbow, 20 Screws)

VKS-58 Snorkel Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)

VKG-58 Ground Floor Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 16 Screws)

P58-48 48" Section Double Wall Pipe, Galvanized

P58-36 36" Section Double Wall Pipe, Galvanized

P58-24 24" Section Double Wall Pipe, Galvanized

P58-12 12" Section Double Wall Pipe, Galvanized

P58-6 6" Section Double Wall Pipe, Galvanized

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galvanized

FPA58-6 6" Dura Vent Collar to FMI Pipe Adaptor

112108-01C

www.desatech.com