Desa DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP Continued, Number Description

Models: DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP (V)DVF36TCRP(E) (V)DVF36TCLP(E)

1 36
Download 36 pages 42.35 Kb
Page 18
Image 18
Number Description

Venting Installation

Instructions

Continued

Number Description

E58-45 45° Elbow, Galvanized

E58-90 90° Elbow, Galvanized

FSE58-45 45° Starter Elbow (Dura Vent to FMI Pipe)

FP-58 Firestop Plate

WF-58 Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

S-58 Vinyl Siding Standoff,

Galvanized

VT-58 Vertical Round Termination, Galvanized

HHT-58 High WInd Round Horizontal Termination Kit, Galvanized

HTS-58 Square Horizontal Termination, Galvanized

HHTK-58 High Wind Round Horizontal Termination Kit

(Includes Round Termination, Wall Firestop, 45° Elbow)

ST-58-14 14" Snorkel Termination,

Galvanized

ST-58-36 36" Snorkel Termination,

Galvanized

SF-58 Stucco Flashing - For use with HTS-58

VR-58 Vertical Restrictor, Galvanized WS-58 Wall Strap

SC-58 Storm Collar, Galvanized

CS-58 Cathedral Ceiling Support

Installation

WALL SWITCH INSTALLATION

The electronic version uses a 24 VAC current sup- plied from a transformer mounted on the ignition module and is prewired for easy connection to a wall switch (see Figure 31). The millivolt version uses a self generated millivolt current that allows you to activate the gas control valve directly with- out the use of normal household electricity (see Figure 32). Both versions are supplied with a wall switch kit for ready connection and mounting.

WALL SWITCH INSTALLATION WARNING: Do not wire re- mote wall switch to main power supply (Standard 120V house- hold current).

1.To remove the louvers, simultaneously pull both top end spring latches towards the center of the appliance until they are disengaged from locating holes. Repeat for bottom spring latches and pull louvers outward. Reverse the procedure to install louvers back onto the ap- pliance (see Figure 33, page 19).

2.Connect the 18 gauge wires from wall switch to the gas control valve terminals marked TH and TPTH or to the ignition module using the pigtails and wire nut connectors supplied with the appliance.

Route 24V (Supplied)

Wall Switch

Through Electrical

 

Conduit Bushing

 

(Supplied)

Electrode

Make Connections

 

 

with Wirenuts

 

 

 

(Supplied)

 

(Back

 

 

 

 

 

 

 

 

View)

Transformer

 

 

 

 

 

 

G

P.

 

 

 

N

 

 

 

D V2 L1 IND TS SI

SW V1

 

Plug 120V AC

Ignition

 

To Receptacle

18 AWG

 

 

Control

 

 

Red Wire

 

 

Module

 

 

 

G

 

P.

 

 

N V2 L1

IND TS SI

SW V1

 

 

D

 

 

 

 

Figure 31 - Wall Switch Wiring Diagram,

Electronic Units

6AI

 

 

7

TH

Wall Switch

 

 

 

TP

(Supplied)

 

TPTH

To

 

 

 

 

Thermopile

 

 

ILOT

 

 

 

P

 

O N

 

16AI

 

T

 

 

 

O

 

7

TH

L

 

I

 

 

 

P

L

I

 

O

O

H

TP

FF

 

 

E

A

 

TPTH

 

 

Route Millivolt Wires

(Back

(Supplied) Through Gas

View)

Line Conduit Sleeve

 

Figure 32 - Wall Switch Wiring Diagram,
Millivolt Units

Note: If any of the original wire supplied must be replaced, use type 18 AWG-105° C (25 feet length maximum) or equivalent.

18

www.desatech.com

112108-01C

Page 18
Image 18
Desa DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP Continued, Wall Switch Installation, Number Description