Ariston PH640MT PR Connection with a rigid pipe copper or steel, Data Plate, Electrical

Models: PH640MST PR PH640MT NG PH640MST NG PH640MT PR

1 12
Download 12 pages 12.5 Kb
Page 4
Image 4
Connection with a rigid pipe (copper or steel)

 

! Check that the pressure of the gas supply is consistent

GB

with the values indicated in Table 1 (“Burner and nozzle

 

specifications”). This will ensure the safe operation and

 

 

longevity of your appliance while maintaining efficient

 

energy consumption.

Connection with a rigid pipe (copper or steel)

!Connection to the gas system must be carried out in such a way as not to place any strain of any kind on the appliance.

There is an adjustable L-shaped pipe fitting on the appliance supply ramp and this is fitted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe fitting (seal provided with appliance). The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment.

Connecting a flexible jointless stainless steel pipe to a threaded attachment

The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment.

These pipes must be installed so that they are never longer than 2000 mm when fully extended. Once connection has been carried out, make sure that the flexible metal pipe does not touch any moving parts and is not compressed.

!Only use pipes and seals that comply with current national regulations.

Checking the tightness of the connection

!When the installation process is complete, check the pipe fittings for leaks using a soapy solution. Never use a flame.

Adapting to different types of gas

To adapt the hob to a different type of gas other than default type (indicated on the rating plate at the base of the hob or on the packaging), the burner nozzles should be replaced as follows:

1.Remove the hob grids and slide the burners off their seats.

2.Unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”).

3.Reassemble the parts following the above procedure in the reverse order.

4.Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Sticker are available from any of our Service Centres.

Adjusting the burners’ primary air : Does not require adjusting.

• Setting the burners to minimum:

1. Turn the tap to the low flame position.

2. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.

!If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

!Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

!Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

DATA PLATE

Electrical

see data plate

connections

 

 

This appliance conforms to the

 

following European Economic

Community directives:

-2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments

-2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments

- 93/68/EEC dated 22/07/93 and subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.

-2002/96/EC and subsequent amendments.

4

Page 4
Image 4
Ariston PH640MT PR Connection with a rigid pipe copper or steel, Checking the tightness of the connection, Data Plate