ACUM140

INSTALLATION AND APPLICATION

 

Item

Units

 

Type of Operation and Application

 

 

60 Hz

 

50 Hz

 

 

 

Prime

 

Standby

 

Prime

 

Standby

 

Rated Speed

rpm

 

1800

 

1500

 

Engine

Gross Engine Output

bhp (kWm)

188 (140)

 

207 (154)

 

164 (122)

 

181 (135)

 

 

 

 

 

 

 

 

 

BMEP

psi (kPa)

230 (1587)

 

253 (1747)

 

201 (1384)

 

221 (1527)

 

 

 

 

 

Mean Piston Speed

Ft/s (m/s)

23.6 (7.2)

 

19.66 (6.0)

 

Ambient Air Temperature

°F (°C)

 

122 (50)

 

 

 

 

 

 

 

 

 

 

 

Engine Heat Reject to Coolant

BTU/min (kW)

4205 (73.9)

 

4534 (79.7)

 

3587 (63)

 

3843 (67.5)

 

 

 

 

 

 

 

 

 

Cooling Sys-

Coolant Capacity

Gal (L)

 

2.6 (9.9)

 

 

tem

Standard Thermostat Range

°F (°C)

 

180-203 (82-95)

 

 

 

Maximum Pressure Cap

Psi (kpa)

 

10 (69)

 

 

 

 

 

 

 

 

Maximum coolant friction

Psi (kpa)

5 (35)

 

4 (28)

 

Total drain flow

gal/h (L/h)

 

 

 

 

 

 

 

 

Fuel Type

 

 

 

Diesel #2

 

Fuel

Fuel Consumption @ 25% Power

gal/hr (L/hr)

2.30

 

2.54

 

2.01

 

2.22

System

Fuel Consumption @ 50% Power

gal/hr (L/hr)

4.61

 

5.07

 

4.02

 

4.44

 

Fuel Consumption @ 75% Power

gal/hr (L/hr)

6.91

 

7.61

 

6.03

 

6.65

 

Fuel Consumption @ 100% Power

gal/hr (L/hr)

9.21

 

10.15

 

8.04

 

8.87

 

Combustion Air Flow

ft3/min (L/s)

391 (181)

 

409 (190)

 

284 (135)

 

302 (144)

Air Require-

Air Intake Restriction clean filter

In.H2O (kPa)

 

10(2.49)

 

 

Air Intake Restriction dirty filter

In.H2O (kPa)

 

25 (6.22)

 

 

ment

 

 

 

Exhaust Temperature

°F (°C)

947 (508)

 

991 (533)

 

1041 (560)

 

1073 (578)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximun Allowable Back Pressure

In.H2O (kPa)

 

40.78 (10.15)

 

 

 

Maximum oil temperature

°F (°C)

 

250 (121)

 

 

Lubrication

Oil Pan Capacity

gal (L)

 

3.8 (14.2)

 

 

 

 

 

 

 

 

 

 

 

Total Engine Oil Cap. w/filter

gal (L)

 

4.3 (16.4)

 

 

System

 

 

 

 

 

 

 

 

 

 

 

 

 

Oil Filter Type

 

 

 

Cartridge

 

 

Lube oil specifications grade

 

 

 

SAE 15W - 40

 

 

Battery Charging Alternator

Volts, Ground

 

 

12V, negative

 

 

 

 

 

 

 

 

 

 

Engine Elec-

Baterry Charging Alternator

Rated amps

 

 

 

55

 

 

 

 

 

 

 

 

 

 

 

Recommended Battery Cold

 

 

 

 

 

 

 

 

tricals

CCA amps

 

 

800 / 0 °F – 18 °C

 

 

Crank

 

 

 

 

 

 

 

 

 

Starter Motor

Volts, Ground

 

 

12V, negative

 

Operation

Temperature and Altidtude Losses

%

4% per 1000 ft (300 m) and 1% per 10°F (2% per 11°C)

 

 

 

 

 

 

 

 

 

 

AR-EXP-CUMMINS-07-00

OWNERS MANUAL

Page 23
Image 23
Armstrong World Industries ACUM210, ACUM84, ACUM185, ACUM65, ACUM110 owner manual ACUM140

ACUM210, ACUM110, ACUM65, ACUM185, ACUM140 specifications

Armstrong World Industries has established itself as a leader in the design and manufacture of innovative ceiling and wall solutions. Among their notable acoustic ceiling offerings are the ACUM84, ACUM210, ACUM65, ACUM140, and ACUM185 tiles. Each of these products is engineered with distinct features and technologies aimed at enhancing acoustic performance, durability, and aesthetics in various commercial spaces.

The ACUM84 is designed for spaces that prioritize sound absorption and overall acoustic quality. It utilizes advanced sound-dampening technology, making it suitable for environments such as offices, schools, and healthcare facilities. This tile achieves a high Noise Reduction Coefficient (NRC), effectively minimizing sound reverberation, which is essential for maintaining concentration in busy settings.

Similarly, the ACUM210 offers enhanced acoustic properties but with a focus on durability. This tile is constructed with a robust material that is resistant to impact and moisture, making it an excellent choice for high-traffic areas. The fabric-like texture not only adds aesthetic value but also improves its sound-absorbing capabilities, contributing to a quieter environment.

For those seeking a versatile solution, the ACUM65 is an ideal option. This tile is lightweight yet durable, making installation straightforward. Its ecological design ensures minimal environmental impact while providing superior acoustic performance. The ACUM65 is particularly well-suited for retail spaces, where customer experience can be significantly enhanced by better sound control.

ACUM140 is engineered for flexibility and design versatility. With a range of finishes and colors, it allows architects and designers to incorporate acoustic solutions that harmonize with the overall aesthetic of the space. Its high NRC rating ensures a calm auditory environment, making it an excellent fit for restaurants and auditoriums.

Lastly, the ACUM185 combines aesthetics with functionality, offering a sleek design while maintaining outstanding sound absorption capabilities. It meets the demands of contemporary styling without compromising performance. This tile is particularly favored in corporate environments where aesthetics play a crucial role in branding and employee satisfaction.

In conclusion, Armstrong's ACUM product line, including ACUM84, ACUM210, ACUM65, ACUM140, and ACUM185, showcases technologies and characteristics that cater to a variety of applications. With a strong focus on acoustic management, durability, and design versatility, Armstrong continues to provide innovative solutions tailored to the needs of modern commercial spaces.