2.1.2 Recommended Installation Tools

You need the following additional tools and equipment to install the switch into an equipment rack:

Flat head screwdriver

Phillips head screwdriver

Antistatic mat or foam

2.1.3 Power Requirements

The electrical outlet should be properly grounded, located near the switch and be easily accessible. Make sure the power source adheres to the following guidelines:

Power: Auto Switching AC, 90-240 VAC

Frequency range: 50/60 Hz

2.1.4 Environmental Requirements

Install the switch in a clean, dry, dust-free area with adequate air circulation to maintain the following environmental limits:

Operating Temperature: 0° to 40°C (32° to 104°F)

Relative Humidity: 5% to 95% non-condensing

Avoid direct sunlight, heat sources, or areas with high levels of electromagnetic interference. Failure to observe these limits may cause damage to the switch and void the warranty.

2.1.5 Cooling and Airflow

The IntraCore IC36240 switch uses internal fans for air-cooling. Do not restrict airflow by covering or obstructing air vents on the sides of the switch.

2.2 Installing into an Equipment Rack

Important: Before continuing, disconnect all cables from the switch.

To mount the switch into an equipment rack:

1.Place the switch on a flat, stable surface.

2.Locate a rack-mounting bracket (supplied) and place it over the mounting holes on one side of the switch.

3.Use the screws (supplied) to secure the bracket (with a Phillips screwdriver).

4.Repeat the two previous steps on the other side of the switch.

11

Asante IntraCore IC36240

Setup Guide

Page 11
Image 11
Asante Technologies IC36240 Series Installing into an Equipment Rack, Recommended Installation Tools, Power Requirements