Ashly 4075, 4150 specifications Architects Specifications, Technical Notes & Specifications

Models: 4075 4150

1 2
Download 2 pages 55.13 Kb
Page 1
Image 1
TRA-Series 4075 and 4150 Four-Channel Amplifiers

TRA-Series 4075 and 4150 Four-Channel Amplifiers

Technical Notes & Specifications

 

 

Architects Specifications

TRA-Series, Lo-Z, 70V/100V 4-Channel Amplifiers

The amplifiers shall have front panel indicators for power, stand-

 

The power amplifiers shall consist of two separate models (4075,

by and protect. Each channel shall have a 6-step signal level

4150), being of four channels, and shall deliver a minimum

meter indicating -24db, -18dB, -12dB, -6dB, -3dB and clip alert.

power of 40 or 80 watts RMS per channel into 8 ohm loads and

 

75 or 150 watts RMS per channel into 4 ohms depending on the

The amplifier shall have built in protection for Output Over-

model being used. The amplifiers shall have internally mounted

Current, DC Output, Main Supply Rail Overvoltage, Chassis

transformers to provide both 70V and 100V constant voltage.

Internal Temperature, Inrush Limiting and Mains Fuse.

Each channel shall deliver a minimum of 75W or 150W, model

 

depending, to the constant voltage lines.

The amplifer shall have a 2-pin Standby Connector to provide

 

for remote standby switching with a 0.5 second turn-on delay.

Dimensions of the amplifiers shall be 19”W x 3.5”H x 11.0”D,

Additionally, the amplifier shall have user selectable Delay

with a weight of 29.5 pounds. The amplifiers shall utilize a state-

Switches to provide incremental turn-on delay when the Standby

of-the-art, efficient, switched mode power supply. The power

connector is used. The switches shall be additive, providing as

supply shall operate at either 120 or 240VAC, 50/60Hz. The

much as 7.5 seconds of delay to the 0.5 second Standby delay.

amplifier shall be convection cooled.

The amplifier shall have a cTUVus safety listing and shall be in

 

The amplifier shall have a selectable input gain of 26dB or 36dB.

compliance with FCC, CE and RoHS regulations.

Frequency response shall be 20 Hz - 20 kHz, +/- 1.0 dB. Hum

 

and noise shall be greater than 98dB and greater than 105dB

The amplifier shall be covered under a full limited warranty of not

repectively below full output (20Hz to 20KHz unweighted).

less than five years. The amplifier shall be an SRA-Series two-

 

channel model, manufactured by Ashly Audio, Inc. of Rochester,

Each amplifier channel shall be supplied with an attenuator

New York.

located on the rear panel. Each input shall have a fixed high pass

 

filter of 12dB/octave at 80Hz.

 

The inputs shall be active balanced design, with an impedance

 

of 20K ohm with a maximum input level of +21dBu. Input con-

 

nections shall be 3-pin Euroblock. Output connectors shall be a

 

screw terminal strip with safety cover.

 

 

 

Features

2RU Chassis

4 Independent Channels

High Efficiency Switched Mode Power Supply

Class-D Output Circuitry

Input Attenuators On Rear Panel

Input Sensitivity 26dB or 36db

Remote Power Turn-On/Off

Adjustable Turn-on Delay

Convection Cooled

6-Step Signal Level and Clip LEDs

Safety/Compliance: cTUVus/FCC, CE, RoHS