Ashly specifications SRA-120Convection Cooled Amplifier, Architects Specifications, Features

Models: SRA-120

1 2
Download 2 pages 63.5 Kb
Page 1
Image 1
SRA-120 Convection Cooled Amplifier

SRA-120 Convection Cooled Amplifier

TECHNICAL NOTES & SPECIFICATIONS

 

 

ARCHITECTS SPECIFICATIONS

SRA-120

barrier strip connections located on the rear panel of the unit. A ground lift strap

The power amplifier, being of two channels, shall deliver a minimum power of

shall be provided to float the input ground from chassis ground if necessary. An

45 watts RMS per channel into 8 ohm loads and 60 watts RMS per channel into 4

input jack on the front panel shall be provided for connection of stereo head-

ohms. When switched into Bridged-Mono mode, the amplifier shall deliver a total

phones. A separate attenuator control for each channel shall also be located on the

of 120 watts RMS into 8 ohms. The amplifier shall be immune to damage from

front panel. There shall be status L.E.D.’s for each channel on the front panel of

shorted, open, or mismatched loads and shall feature independent thermal protec-

the amplifier to indicate signal present, clip alert, and “protect mode”. Power

tion, turn on delay, and instantaneous turn-off. The amplifier shall have a gain of

requirements of the amplifier shall be 350W max, 30W idle @ 120VAC, 50Hz-

26 dB + .2dB per channel. The input sensitivity shall be selectable between

60Hz. For use in other countries, the unit shall also be available as a 240VAC

.775Vrms or .245Vrms via a rear panel switch. Frequency response shall be 20Hz to

model. The unit shall be one rack space (1.75”) high and no more than 10” deep.

20kHz + .2dB. The amplifier shall be stable into any load, including pure capaci-

The amplifier must be convection-cooled, with large, extruded aluminum heat sinks

tors and inductors. Hum and noise shall be at least 100dB below full output and

with vertically oriented fins located on each side of the unit. The shipping weight

SMPTE intermodulation distortion shall be less than .01% at full output. To mini-

of the unit shall be 20 pounds. The amplifier shall be covered under a full limited

mize hum and reduce overall weight, the unit shall utilize a toroidal power supply

warranty of not less than five years. The amplifier must be made in the USA. The

transformer.

amplifier shall be the model SRA-120, manufactured by Ashly Audio, Inc. of

The amplifier shall have rear panel switching for mono or stereo and bridging

Rochester, New York.

 

modes. The inputs shall be of balanced bridging type with both 1/4” phone and

 

 

 

Features:

Convection Cooled

Class-A Full Complementary Front End

Stereo, Mono & Bridging Modes

Barrier Strip and 1/4" Inputs

Input Sensitivity Select Switch

Turn-on Delay

Instantaneous Turn-off

Independent Thermal Protection

5-Year Worry-Free Warranty

Page 1
Image 1
Ashly specifications SRA-120Convection Cooled Amplifier, Architects Specifications, Technical Notes & Specifications