Three output expansion cards
added
Complete post-mixer system
processor for all speaker locations
Electrical box mounted remote
DC level controller for DressingRooms
Three input expansion
cards added
Four independent room
systems can easily bereconfigured using contactclosure preset recall
Electrical box mounted
remote DC level controller foreach room
Use Remote Level Control
input to mute channels duringemergency
Fire alarm drives relay when
active. Relay connectsne24.24M 0-5V Remote LevelControl Ground to desired pin,muting all channels assigned insoftware (see sec. 10.1)
Mixing
Console
Output
1
2
3
4
Inputs
1-3
4-6
7-9
10
11
12
Outputs
L
C
R
Subs
Under Balcony
(Delay)
Lobby
13-14
LCR Inputs:
- Ducked Signal
Mic Input:
- Ducking Input
LCR Outputs:
- HPF / LPF
- Alignment Delay
- EQ
- Limiter
Dressing Room
- Wall Mount
Remote Level
Control

Left / Center / Right

Theater System L
C
R
Dressing Room
Paging Mic
15-16 Dressing
Room 3&4
Dressing
Room 1&2
HF
MF
LF
HF
MF
LF HF
MF
LF
Remote
Control
1
Inputs Outputs
Conference Center
System
AV Input
2
3
4
Meeting Room 1
Room Divider
1Ceiling Speakers
Room Volume Control
5
AV Input
6
7
8
Meeting Room 2 2Ceiling Speakers
Room Volume Control
9
AV Input
10
11 Ballroom 1
Room Divider
3Main Speakers
Room Volume Control
Ballroom 2 4Main Speakers
Room Volume Control
Portable Mixer Output 12
13
AV Input
14
15
Portable Mixer Output 16
Contact Closure
Preset Panel for
Room Combining
ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580Phone: (585) 872-0010 Fax: (585) 872-0739Toll Free (800) 828-6308 www.ashly.com © 2008Ashly Audio Corporation R0
Fire Alarm Mute
Configuration

Emergency Alarm System

Connector on
ne24.24M
Back Panel
Alarm Relay
Drive Output
Relay (shown alarm off)
Switched Ground
To Desired Pin for
Mute All Function