FLASH UPGRADE USER GUIDE | IMPRESSION A10+/A9+/A8+ |
|
|
6. SENDING THE FILE (SW&HW)
1.Flashing the SW EPROM: Type RRP;38400 and press Enter.
2.Flashing the HW EPROM: Type FPG;38400 and press Enter.
It is not necessary to use capital letters, but the command must be written exactly as described, otherwise the projector will return “Undefined Command..”. This will also happen if you type incorrectly or try to erase text.
3.On “Hyperterminal”, close the connection by clicking on the “hang up phone icon”.
4.Go into “File Properties” and press “Configure”.
5.Use the ADVANCED /SERVICE / INFO
“Bits per second” | 38400 Baud |
“Data bits” | 8 bit |
“Parity” | None |
“Stop Bits” | 1 bit |
“Flow control” | None |
6.
7.Open the transfer menu and select “Send File…”
8.Browse so that the correct BIN file, which can be found on the Proxima web page under “MLS resources Firmware.., can be selected and inserted in the file name field. It will be explained on the web page which BIN file (HW or SW) requires the different RS232 commands (RRP or FPG). Both the SW bin and the HW bin file are 805.xxx#.bin files.
9.Set protocol to Xmodem as described in figure below. Filename should read the name of the BIN file you have selected.
PROXIMA ASA | 7 |
|
|