the table.
AC Adapter
Item | Specification |
|
|
Vendor & model name | Liton, 135W power supply |
|
|
Input Voltage |
|
|
|
Low Range | |
|
|
High Range | |
|
|
Input current | 2.2A(max) |
|
|
Nominal frequency (Hz) | |
|
|
Frequency variation range (Hz) | |
|
|
Efficiency | It should provide an efficiency of 85% minimum, when measured at maximum |
| load under 115Vac. |
|
|
Output Requirements |
|
|
|
DC output voltage | 19V |
|
|
Noise + Ripple | 380mV as output voltage is 19V |
|
|
Peak Load | |
|
|
Dynamic Output Characteristics |
|
|
|
5 sec (@ 115Vac) | |
|
|
Hold up time | 5ms (@115Vac, Full load) |
|
|
Over Voltage Protection (OVP) | 29V |
|
|
Short circuit protection | 9.5A @19V output voltage |
|
|
Electrostatic discharge (ESD) | 15KV (at air discharge) |
| 8KV (at contact discharge) |
|
|
Dielectric Withstand Voltage |
|
|
|
Primary to secondary | 2150VDC for 1 sec. |
|
|
Ground leakage current | less than 250uA |
|
|
Power Management
Power Saving Mode | Phenomenon |
|
|
Standby Mode | The buzzer beeps |
Enter Standby Mode when | The Sleep indicator lights up |
| |
1.Standby/Hibernation |
|
and system is not ready to enter Hibernation |
|
mode. |
|
2.System standby/ Hibernation timer expires |
|
and system is not ready to enter Hibernation |
|
mode. |
|
|
|
Hibernation Mode | All power shuts off |
Enter Hibernation Mode (suspend to HDD) |
|
when |
|
1.Hibernation |
|
system is ready to enter Hibernation mode |
|
2.System Hibernation timer expires and |
|
system is ready to enter Hibernation mode. |
|
Display Standby Mode | The display shuts off |
Keyboard, |
|
PS/2 pointing device are idle for a specified |
|
period. |
|
|
|
Hard Disk Standby Mode | Hard disk drive is in standby mode. |
Hard disk is idle within a specified period of | (spindle |
time. |
|
|
|
Chapter 1 | 31 |