2.1Before you proceed

Take note of the following precautions before you install the server management board to the server system.

Unplug the server system power cord from the wall socket before

touching any component.

Use a grounded wrist strap or touch a safely grounded object or to a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity.

Hold components by the edges to avoid touching the ICs on them.

Whenever you uninstall any component, place it on a grounded antistatic pad or in the bag that came with the component.

Before you install or remove any component, ensure that the power supply is switched off or the power cord is detached from the power supply. Failure to do so may cause severe damage to the motherboard, peripherals, and/or components.

2.2Hardware installation

To install the server management board:

1.Remove the server system cover, then locate the Baseboard Management Controller (BMC) socket on the motherboard.

Refer to the Appendix section for the location of the BMC socket on supported motherboards.

2.Position the board at a 30º-45º angle, then match the notch on the board with the break on the socket.

2 - 2

Chapter 2: Installation