(p. 5-149) (p. 5-192)
(p. 5-4) (p. 5-4)

System Programming Quick Reference

Place the Programming Overlay on the dial pad of the system display phone at extension 10 or 11

TO START SYSTEM PROGRAMMING TO END SYSTEM PROGRAMMING

PRESS [ Feature ] [ 0 ] [ 0 ]

PRESS [ Feature ] [ 0 ] [ 0 ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESS [ System Program ]

TO USE A SPECIFIC PROCEDURE

PRESS [ System Program ]

DIAL [ # ] and three-digit procedure code

 

 

 

 

 

 

 

 

 

 

 

 

Example: [ # ] [ 1 ] [ 0 ] [ 1 ] for System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date

TO CYCLE THROUGH SYSTEM

TO CYCLE THROUGH AVAILABLE

PROGRAMMING PROCEDURES

SETTINGS

PRESS [ Next Procedure ] or [ Prev Procedure ]

PRESS [

Next Data

] or [

Prev Data

]

 

 

 

 

 

TO RETURN TO FACTORY

NOTE: Procedures #399, #609,

and #728—shown below in dashed

SETTING

boxes—are skipped when cycling.

PRESS [ Remove ]

Extensions

LINE ASSIGNMENT

 

P+ >

R1.0

(p. 5-85)

PII >

R1.0

(p. 5-118)

DIAL #301

DIAL an extension number (10-33 P+, 10–57 PII)

To remove all existing line assignments, press [ Remove ] before selecting a line.

DIAL a line number (01–12 P+,01– 24 PII)

DIAL 1 = Assigned 2 = Not Assigned

3 = Select Button then press a programmable button (to assign the line to that button)P+ > R3.0, PII > R1.0

If you use option 3 after a line has been assigned, the line moves from the old button to the new button you select.

PRESS [ Next Item ] to program another line for this extension.

To program another extension:

PRESS [ Next Procedure ] [ Prev Procedure ],

enter a new extension num- ber, and repeat above steps

LINE ACCESS RESTRICTION

P+ >

R1.0

(p. 5-83)

PII >

R1.0

(p. 5-116)

DIAL #302

DIAL an extension number (10–33 P+,10-57 PII)

DIAL a line number (01–12 P+,01– 24 PII)

DIAL 1 = No Restriction 2 = Outgoing Only 3 = Incoming Only

4 = No Access (line appears on button, but you can use line only to pick up a transferred or held call)

PRESS [ Next Item ] to program another line

To program another extension:

PRESS [ Next Procedure ] [ Prev Procedure ] ,

enter a new extension num- ber, and repeat above steps

DISPLAY LANGUAGE

 

P+ >

R1.0

(p. 5-45)

PII >

R1.0

(p. 5-76)

DIAL #303

DIAL an extension number (10–33 P+, 10-57 PII)

DIAL 1 = English 2 = Spanish 3 = French

PRESS [ Next Item ] to program another extension

AUTOMATIC EXTENSION PRIVACY

P+ > R1.0

(p.

5-17)

PII >

R1.0

(p.

5-17)

DIAL

#304

 

 

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Assigned

2 = Not Assigned PRESS [ Next Item ] to program another

extension

ABBREVIATED RINGING

P+ > R1.0

PII > R1.0

DIAL #305

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Active (1 ring)

2 = Not Active (repeated ringing)

PRESS [ Next Item ] to program another extension

TRANSFER RETURN

EXTENSION

P+ > R2.0

PII > R1.0 R 2 . 0

DIAL #306

DIAL an extension number (10–33 P+,10-57 PII)

DIAL number of the extension (10– 33 P+,10-57 PII) to which call should return if not answered

Extension transferring call

PRESS [ Next Item ] to program another extension

FORCED ACCOUNT CODE ENTRY

P+ > R3.0

(p.

5-58)

PII > R3.0

(p.

5-90)

DIAL #307

 

 

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Assigned

2 = Not Assigned

PRESS [ Next Item ] to program another extension

DISTINCTIVE RING

 

 

P+ > R3.0

(p.

5-46)

PII > R3.0

(p.

5-77)

DIAL #308

 

 

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Active 2 = Not Active

PRESS [ Next Item ] to program another

extension

INTERCOM DIAL TONE

P+ >

R3.0

(p. 5-79)

PII >

R3.0

(p. 5-111)

DIAL #309

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Regular 2 = Machine

PRESS [ Next Item ] to program another extension

AUTOMATIC VMS COVER

P+ > R3.1

(p.

5-20)

PII > R3.0

(p.

5-32)

DIAL #310

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Assigned

2 = Not Assigned

PRESS [ Next Item ] to program another extension

EXTERNAL HOTLINE

(was EMERGENCY TELEPHONE)

P+ > R3.1

(p.

5-55)

PII > R3.0

(p.

5-87)

DIAL #311

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Assigned

2 = Not Assigned PRESS [ Next Item ] to program another

extension

VOICE INTERRUPT ON BUSY

P+ > R3.1

(p. 5-156)

PII > R3.1

(p. 5-200)

DIAL #312

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1

= Assigned

2

= Not Assigned

PRESS [ Next Item ] to program

 

another

extension

 

 

 

 

 

LINE ACCESS MODE

PII > R4.0

 

(p. 5-115)

DIAL #313

DIAL an extension number (10–57)

DIAL 1 = Pool all extensions except 10

2 = Key extension 10 only

POOL EXTENSION ASSIGNMENT

PII > R4.0

(p. 5-154)

DIAL

#314

 

DIAL

an extension number (10–57):

 

To remove all existing pool

 

assignments, press [ Remove ]

 

before selecting a line.

DIAL

a pool access code (880,

 

881, 882, or 883)

 

DIAL

1 = Assigned 880

 

2 = Not Assigned 881,

 

882, 883

 

 

3 = Select Button then

press a programmable button (auxiliary pools only)

PRESS [ Next Item ] to program another pool for this extension.

To program another extension:

PRESS [ Next Procedure ] [ Prev Procedure ],

enter a new extension number, and repeat above steps

POOL ACCESS RESTRICTION

PII > R4.0

(p. 5-152)

DIAL #315

 

DIAL an extension number (10–57)

DIAL a pool number (880, 881, 882, or 883)

DIAL 1 = No Restriction 2 = Outgoing Only 3 = Incoming Only 4 = No Access

PRESS [ Next Item ] to program

another pool

To program another extension:

PRESS [ Next Procedure ] [ Prev Procedure ],

enter a new extension num- her, and repeat above steps

CALL WAITING

 

P+ >

R4.0

(p. 5-30)

PII >

R4.0

(p. 5-47)

DIAL #316

DIAL an extension number (10–33 P+,10-57 PII)

DIAL 1 = Assigned

2 = Not Assigned

PRESS [ Next Item ] to program another extension

COPY SETTINGS

 

P+ >

R1.0

(p. 5-35)

PII >

R1.0

(p. 5-57)

DIAL #399

DIAL a source extension number DIAL target extension numbers

6

Page 6
Image 6
AT&T MG9150J manual Extensions

MG9150J specifications

The AT&T MG9150J is a robust broadband gateway designed to meet the growing connectivity needs of modern homes and small businesses. This device combines advanced technologies and features to deliver seamless internet access, supporting multiple devices with high-speed connectivity.

One of the standout features of the MG9150J is its compatibility with the latest Wi-Fi 6 (802.11ax) standard. Wi-Fi 6 enhances overall network performance by allowing more devices to connect simultaneously without degradation in speed. This is particularly beneficial in households with multiple smart devices, including smartphones, tablets, laptops, and IoT devices. Additionally, Wi-Fi 6 supports improved efficiency through features like MU-MIMO and OFDMA, enabling better multi-user performance and reduced latency.

The AT&T MG9150J is equipped with dual-band capabilities, operating on both 2.4 GHz and 5 GHz frequency bands. This flexibility allows users to connect their devices based on their specific needs. The 2.4 GHz band provides longer range and better penetration through walls, while the 5 GHz band offers higher speeds and is less prone to interference, making it ideal for activities that require a stable and fast connection, such as gaming and streaming.

Another significant characteristic of the MG9150J is its integrated security features. Equipped with advanced wireless security protocols, the device helps protect user data and maintain privacy. Features such as WPA3 encryption enhance protection against unauthorized access, ensuring that networks remain secure from potential threats.

The gateway also supports advanced Quality of Service (QoS) settings, which allow users to prioritize bandwidth to specific applications or devices. This feature is particularly useful for households where multiple users engage in bandwidth-intensive activities simultaneously, such as video conferencing or online gaming.

Additionally, the AT&T MG9150J is designed with user-friendly setup and management options. It typically includes a mobile app that enables users to monitor their network, manage connected devices, and adjust settings remotely. This convenience enhances the overall user experience by making network management easier and more accessible.

In conclusion, the AT&T MG9150J stands out as a comprehensive gateway solution, combining cutting-edge technologies, innovative features, and user-centric design. With its support for Wi-Fi 6, dual-band capabilities, robust security measures, and enhanced management options, it meets the demands of today’s digital lifestyle, providing reliable and high-speed internet access for all users.