Appendix

Administrator Login Failure

If you are unable to perform an Administrator login (because the Username and Password information has become corrupted or you have forgotten it, for example) you can clear the login information with the following procedure:

1.Power off the KH0116 and remove its housing.

2.Short the jumper labeled J12.

1

PW-JACK

1 7SEG-A

1 FWDL-B

J12

1 LEA-A

 

 

 

Restore

 

 

 

 

Default

 

 

 

 

Password

 

250-B2

 

 

 

 

1

250-B1

1

 

 

 

1

 

 

 

 

 

 

CMS

CHAIN IN

PC8

PC7

PC6

PC5

PC4

PC3

PC2

PC1

CVGA

 

 

CHAIN OUT

HD15-F

HD15-F

HD15-F

HD15-F

HD15-F

HD15-F

HD15-F

HD15-F

CKB

 

 

 

 

 

 

 

 

 

3.Power on the switch.

The on screen display will show a message informing you that the password information has been cleared.

4.Power off the switch.

5.Remove the jumper cap from J12.

6.Close the housing and start the KH0116 back up.

After you start back up, you can use the default Username and Password (see OSD Overview, p. 33) to log in.

51