 | INSTRUCTION | MANUAL | |
| 
 | 
 | 
 | 
 | ATHENA 6050 | ||
| 
 | 
 | 
 | 
 | Automatic | Tuning | |
| 
 | 
 | 
 | 
 | Temperature | Controller | |
| SPECIFICATIONS: | 
 | 
 | 
 | |||
| Inputs: | 
 | 
 | 
 | 
 | 
 | |
| Line Voltage | 120/240 Vac +lO%,  | |||||
| Sensor | 
 | 
 | 
 | Thermocouple | ||
| Power | Consumption | Less than 6 VA (Instrument) | ||||
| Ranges | Available | J Couple  | ||||
| 
 | 
 | 
 | 
 | K Couple  | ||
| Accuracy: | 
 | 
 | 0.2% | of | full scale | |
| Temperature | Stability | 5 m V/°C Max 3m V/°C typ. | ||||
| Cold end | tracking | 0.05°C/°C ambient | ||||
| Operating | ambient for | 
 | 
 | 
 | ||
| rated | accuracy | 0 to 55°C | ||||
| Maximum T/C | lead | 
 | 
 | 
 | ||
| resistance for | 
 | 
 | 
 | |||
| rated | accuracy | 100 Ohm | 
 | |||
| Series | mode | noise | 
 | 
 | 
 | |
| rejection: | 
 | 80 dB | 
 | 
 | ||
| Common | mode | noise | 
 | 
 | 
 | |
| rejection | 
 | 
 | 120 dB | 
 | ||
| T/C break | protection: | Upscale | standard | |||
| Dual display: | Process | temperature displayed | ||||
| 
 | 
 | 
 | 
 | continuously; set point or other | ||
| 
 | 
 | 
 | 
 | parameters updated on lower display. | ||
1