CP700 COMMERCIAL POWER AMPLIFIER

INPUT WIRING

OWNER'S MANUAL

Balanced Inputs

Balanced input wiring requires two conductors with shield (22 gauge is the most common). The use of crimp type spade lugs is highly recommended for permanent installations. At the input section located on the rear of the CP700, wire the "hot"/positive lead to the "+" terminal, the "cold"/negative lead to the "-" terminal and the shield/drain to the "ground" terminal.

The XLR inputs (+4dB balanced line level) can be utilized with standard 3-pin XLR male to female patch cables to accommodate outputs from a mixer, equalizer or crossover when the CP700 is used as a portable sound system amplifi er (Figure 3).

White (+)

White (+)

Black (-)

Black (-)

Shield

Shield

IN

IN

AMPLIFIER

 

-2

-1

+ - GND -

+

THRU

GND

 

 

 