Owner’s Manual | PA1001G Power Amplifier |
|
|
1 | 5 | 11 |
3 | 2 | 4 | 10 | 6 | 7 | 8 | 9 |
Rear Panel
1.IEC AC Receptacle
Connect this grounded power cord to 100VAC - 240VAC 50/60Hz circuits only. Serious damage may result otherwise.
2.AC Mains Fuse
For 100v - 240v 50Hz - 60Hz operation use Slow Blow T1.6AL 250v, 5mm x 20mm.
Note: Fuse is internal and should only be changed by a qualified technician.
3.UNSWITCHED OUTLET
The
4.RCA Input
Unbalanced signals are accepted when using the Left and Right RCA connectors. These inputs are electrically summed into a mono signal. Note: On the bottom of the chassis there are level controls for the for the Left and Right RCA inputs. This allows you to adjust the level from OFF to +6dB. Factory settings calibrated for 320mv of input sensitivity. See Mixer Function page 9 for use.
5.AC Fault LED
This LED will illuminate Red if a fault has occured with the AC spike supression circuity. Usually cause for this is a lightning strike, causing a voltage surge. The AC Unswitched outlet may still function but there may be no AC surge or Spike supression protection for the product connected to the outlet. It is recommended to have the amplifier looked at by certified technician.
6.Balanced Input Connections
Left and Right balanced input signals can be accomplished by wiring the removable Phoenix type connector per the labeling on the rear of the amp. Note: The middle pin is the common ground connection for both Left and Right input ground. For unbalanced signals connect the
7.Speaker Connections
A removable Phoenix type connector is supplied to connect your speakers to the PA1001G. It is recommended to use 16guage wire or higher for connection to the speaker. Note: Do not overload the amp by connecting to many speakers to the amp. Four ohms per channel is the maximum load.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 7 – | AtlasSound.com |
Specifications are subject to change without notice.