RS-232 SERIAL INTERFACE
1. Connect a PC or Control System
Pin | Definition | |
1 | - | Not used |
2 | TX | Transmitter |
3 | RX | Receiver |
4 | - | Not used |
5 | GND | Ground |
6 | - | Not used |
7 | - | Not used |
8 | - | Not used |
9 | - | Not used |
2. RS232
Atlona’s
The serial communication parameters are 9600 baud, 8 bit, No Parity and 1 stop bit
When the unit recognizes a complete command it will perform the requested action - there is no delimiter character required.
The unit does not send out a message when a value is changed from the front panel or by IR control. If the unit needs to be controlled via the front panel in addition to the RS232 control, you should regularly poll the unit status to ensure the control system accurately relate the current settings.
3. PROTOCOL COMMANDS
To Switch Inputs to Outputs
SBI0XO0Y - Where X is Output Number
Unit will respond with
SBUD0XOY - Where X is Output Number
Example : Send Input 6 to Output 4
SBUD06O4 – Send
SBI06O04 – Rcvd
5