TROUBLESHOOTING
Question: My Display/Adapter will fail to “wake up” from sleep mode?
Answer: Press the reset button on the front of the unit. The reset function will reload the EDID and display with the best resolution image. This is not standard issue; however may happen with older computers.
Question: My Mac works fine; however my PC is not connecting to the monitor though your converter?
Answer: a) We suggest to make sure that you have the following output resolutions selected on your computer: iMac 27” (2560x1440) and Apple 24” LED (1920x1200)
b)Please perform a Bios update to make sure you have the latest version. Please update your video card and USB drivers to the latest drivers.
c)Press “reset” button on the DP400 to trigger a pull of the EDID from the display to the computer
Question: I want to connect my PS3 to my monitor using your box? Please help.
Answer: We do suggest using
Question: My iSight camera and speakers won’t work when I use your unit.
Answer: The iSight operates through the usb of the 24” LED Display, Please plug in the USB from the monitor to your computer.
Question: How can I control the brightness on my monitor when using your device?
Answer: The brightness settings can only be adjusted on Apple made computers.
Question: What does the Green Light mean on the DP400?
Answer: The green light indicates that your laptop or desktop is connected to the DP400 and the Monitor correctly. It also means the unit is powered up successfully through the usb.
Question: What does the Red Light mean on the DP400?
Answer: The Red light can mean that the unit isn’t being powered on correctly. Please