2. RS232

The Atlona switcher is featured with RS232 control port which allows users to control the switch though a control system or from the computer.

The serial communication parameters are 9600 baud rate, 8 bit, No Parity and 1 stop bit

When the unit recognizes a complete command it will perform the requested action - there is no delimiter character

required.

Note: The unit does not send out a feedback message when a value is changed from the front panel or by IR control. If the switcher needs to be controlled though front panel in addition to the RS232 control, user should regularly verify the unit’s status to ensure the control system accurately reflects the current settings.

3. Protocol Commands

To Switch Inputs to Outputs

SBI0XO0Y - Where X is Output Number (1-1) and Y is Input Number (1-4)

Unit will respond with

SBUD0XOY - Where X is Output Number (1-1) and Y is Input Number (1-4)

Example: Send Input 4 to Output 1 SBI04O01 – Sending Command

SBUD04O1 – would be the feedback command which switcher will send back to the control system to confirm

the input change

4. RS-232 Serial Commands

Power OFF command - SBSYSMOF

Power ON command - SBSYSMON

Unit will respond with:

Unit is in Standby - SBALOFAK

Unit is no longer in Standby - SBALONAK

Example: Put Unit in Standby (Soft Power) SBSYSMOF

Switchers will feedback with SBALOFAK

5. Front Panel Lock

Note: Hard resetting the unit will unlock the Front Panel controls.

Lock Front Panel: SBSYSMLK – When locked, changes can only be made via RS232

Unlock front panel: SBSYSMUK

Unit will respond with: SBSYSLOK - Front Panel has been locked

SBSYSULK - Front Panel has been Unlocked

SBALLRST - Reset every output to Input 1

Unit will respond with SBRSTACK

Toll free: 1-877-536-3976