RS232 COMMUNICATION PROTOCOL

Baud rate: 9600 - Data bit: 8 - Stop bit: 1 -Parity bit: none

Command

Function Description

Feedback Code

1A1.

Switching audio input to input 1

A : 1 -> 1

2A1.

Switching audio input to input 2

A : 2 -> 1

 

 

 

0A0.

Mute the Audio

Mute Audio

0A1.

UnMute the Audio

UnMute Audio

1A0.

Mute the Mic audio

Mute Mic

2A0.

Mute the Line Out audio

Mute LIN

600%

Current Status of the PA100

A: 1 -> 1

 

 

Volume : 30

 

 

Bass 00

 

 

Treble 00

601%

MIC volume up

Volume of MIC : 51

602%

MIC volume down

Volume of MIC : 51

603%

Line volume up

Volume of LINE : 51

604%

Line volume down

Volume of LINE : 51

605%

Bass volume up

Bass of LINE : 04

606%

Bass volume down

Bass of LINE : 04

607%

Treble volume up

Treble of LINE : 04

608%

Treble volume down

Treble of LINE : 04

609%

Reset to default settings

A : 1 -> 1

 

 

Volume : 50

 

 

Bass 07

 

 

Treble 07

5[x][x]%

Preset MIC volume, [xx] is set from [00] to [60]. 61 degrees in total

Volume of MIC : 50

7[x][x]%

Preset line volume, [xx] is set from [00] to [60]. 61 degrees in total

Volume of LINE : 50

8[x][x]%

Preset bass volume, [xx] is set from [00] to [08]. 9 degrees in total

Bass of LINE : 04

9[x][x]%

Preset treble volume, [xx] is set from [00] to [08]. 9 degrees in total

Treble of LINE : 04

 

 

 

Notice:

1:The characters inside bracket [ ] are the variable code, which is the changeable.

2:The bracket [ ] is not included in the RS232 commands.

Example 1: Switching the input 2 to the line-out should be [2A1.]

Example 2: Turning up the volume of the line audio should be [603%]

Example 3: Preset the MIC volume to be “21” degree should be [521%]