Attwood 6126 installation instructions Potable Water Pump, Mounting Instructions

Models: 6126

1 1
Download 1 pages 59.54 Kb
Page 1
Image 1

Potable Water Pump

6126

Mounting Instructions

SAVE THESE INSTRUCTIONS

 

Form Number 69239 Rev. B

03-11

FEATURES:

The Potable Water Pump is a rugged, small sized fresh water pump used to deliver water to a faucet. Ideal for use with the Attwood 6142 Faucet/Hand Pump. It is made of ABS non-corro- sive FDA approved plastic. Meets U.S. Coast Guard Safety Standards Sections 33 CFR 183.410 and 183.425. Listed by the International Association of Plumbing and Mechanical Officials (IAPMO).

Attwood marine hardware, navigation lighting, interior lighting, bilge pumps, and other marine accessories are specified more than any other brand by America’s best-known boat manufacturers as original equipment. Look to Attwood for quality replacement parts and add-on marine accessories.

CAUTION:

The Potable Water Pump is designed to pump fresh, potable water only. It must not be used to pump gasoline or other flammable liquids.

TOOLS AND MATERIALS REQUIRED:

1.Drill and suitable drill bits.

2.Screwdriver.

3.Wire strippers.

4.Four (4) wire connectors or equivalent.

5.One (1) in-line fuse holder with 2 amp fuse.

6.Two (2) #10 panhead screws (length must not protrude through deck).

7.Suitable length of 3/8" I.D. hose for pump to tank and pump to faucet.

8.Four (4) stainless steel screw-adjustable hose clamps.

9.Additional wire, if needed, in 16 or 18 gauge size.

INSTALLATION INSTRUCTIONS:

1.Select a suitable location for this pump, keeping in mind that it must be a dry area.

The pump has intake and outlet fittings to fit 3/8" I.D. soft plastic tubing or 1/4" female pipe thread (cut off hose barb if necessary). Teflon® plumbers tape must be used for all threaded connections and hose clamps for all tubing con- nections.

NOTE: This product is designed to be used with the Attwood 6142 3-Way Electric Faucet which includes an integral ON/OFF switch. However, it may also be used with any 12 volt DC water system with an ON/OFF switch rated for 2 amps (or more) serv- ice providing that the recommended 2 amp fuse is also used.

2.After installing the pump, connect the pump’s black lead wire directly to the 12 volt battery negative (-) connector. Connect the pump’s brown wire lead to one wire of an in-line fuse holder and connect the other fuse holder wire to one lead wire from the Electric Faucet. Connect the other Electric Faucet lead wire directly to the 12 volt battery positive (+) connector. (See Figure 1). Added wire must be 18 gauge or larger.

An optional power ON/OFF switch, such as Attwood 7589 or 7563, may be installed as a master switch as shown in Figure 2.

The pump may be threaded directly into the tank. However, this is a centrifugal pump and must be positioned lower than the source of water to operate. Do not install on a surface higher than the bottom of your fresh water supply tank.

NOTE: When installing, outlet nozzle should always be higher than inlet nozzle. (See Figure 3)

WIRE CONNECTORS

 

BLACK

Attwood 6142

BROWN

3-WAY ELECTRIC FAUCET

 

CITY WATER

CONNECTION

30-40 PSI

FUSE AND

HOLDER

PRESSURE

 

LIMITING

 

VALVE

 

 

CHECK TEE

 

VALVE

 

WIRE

 

CONNECTORS

 

BLACK

BROWN

WATER SUPPLY TANK

12VOLT BATTERY

Attwood 6126

POTABLE WATER PUMP

FIGURE 1

OPTIONAL

MASTER SWITCH

INSTALLATION

BROWN

BLACK

 

 

 

Attwood

 

 

7589 or 7563

 

BROWN

SWITCH

TO

TO POTABLE

BATTERY

 

WATER PUMP

FIGURE 2

OUTLET ABOVE INLET

INLET

INLET

OUTLET BELOW INLET

INCORRECTCORRECT

FIGURE 3

CAUTION:

This product is not water resistant and must be installed in a dry location.

Do not use synthetic rubber sealant (Silicone, RTV, etc.) or any sealant which smells like vinegar to seal the pump or its fittings. Use of these materials may cause the pump to crack. It is best to use plumbers Teflon® tape where required.

CAUTION:

ALWAYS protect the pump and the wiring with a 2 amp fuse. For 12 volt DC use only.

ATTWOOD LIMITED WARRANTY

BILGE PUMPS

ATTWOOD CORPORATION, 1016 North Monroe, Lowell, Michigan 49331, (“Attwood”) warrants to the original consumer purchaser that this Attwood Potable Water Pump will be free from defects in materials and workmanship under normal use and service for a period of one (1) year from the date of original consumer purchase. This warranty does not extend to any batteries or fuses used with the pump. This limited warranty is not applicable if the pump has been damaged by accident, improper installation, unreasonable use, lack of proper maintenance, unauthorized repairs or modifications, or other causes not arising out of defects in materials and workmanship.

Attwood’s obligations under this warranty are limited to repair of the product at Attwood’s plant or replacement of the product at Attwood’s option and at Attwood’s expense. Any expenses involved in the removal, reinstallation, or transportation of the product are not covered by this warranty. The product must be returned to Attwood’s plant at the address indicated above, postage prepaid, with proof of original purchase, including date. If Attwood is unable to replace the product and repair is not commercially practicable or cannot be timely made, or if the original consumer purchaser is willing to accept a refund in lieu of repair of replacement, Attwood may refund the purchase price, less an amount for depreciation. The acceptance by Attwood of any product returned or any refund provided by Attwood shall not be deemed an admission that the product is defective or in violation of any warranty.

This warranty is Attwood’s only express warranty of this product. No implied warranty shall extend beyond one (1) year from the date of original consumer purchase. Attwood shall not be liable for any damages for loss of use of this product, nor for any other incidental or consequen- tial damages, costs or expenses.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

© 2003 Attwood Corporation

 

1016 N. Monroe Street, Lowell, MI 49331-0260

www.attwoodmarine.com