ATWOOD ELECTRIC WATER HEATER | 5. | Return parts (or water heater) must be shipped to Atwood “Prepaid”. Credit for |
| shipping costs will be included with the warranty claim. The defective parts (or | |
LIMITED WARRANTY |
| water heater) become the property of Atwood Mobile Products and must be |
Atwood Mobile Products warrants to the original owner and subject to the below |
| returned to the Consumer Service Department, Atwood Mobile Products, 6320 |
mentioned conditions, that this product will be free of defects in material or |
| Kelly Willis Road, Greenbrier, TN 37073 USA. |
workmanship for a period of two years from the original date of purchase. | 6. | This warranty applies only if the unit is installed according to the |
Atwood’s liability hereunder is limited to the replacement of the product, repair of |
| instructions provided and complies with local and state codes. |
the product, or replacement of the product with a reconditioned product at the | 7. | The warranty period on replacement parts (or water heater) is the unused |
discretion of the manufacturer. This warranty is void if the product has been |
| portion of the original warranty period or ninety (90) days, whichever is greater. |
damaged by accident, unreasonable use, neglect, tampering or other causes not | 8. | Damage or failure resulting from misuse (including failure to seek proper repair |
arising from defects in material workmanship. This warranty extends to the original |
| service), misapplication, alterations, water damage, or freezing are the owner’s |
owner of the product only and is subject to the following conditions: |
| responsibility. |
1. For a period of two years from the date of purchase, Atwood will replace the | 9. | Atwood does not assume responsibility for any loss of use of vehicle, loss of |
complete water heater if the inner tank leaks due to corrosion. This warranty |
| time, inconvenience, expense for gasoline, telephone, travel, lodging, loss or |
|
|
|
|
| LITERATURE NUMBER MPD 93757 |
|
|
|
|
| MARINE WATER HEATER |
|
|
|
| 9 | ALL ELECTRIC |
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
| •Installation •Operation •Maintenance |
|
|
|
|
| |
ENGLISH, FRANÇAIS (CANADA) |
| ||||
| Effective 11/19/07 | ||||
|
|
|
|
|
|
| includes reasonable labor charges required to replace the complete water heater. | damage to personal property or revenues. Some states do not allow the |
2. | For two years from the date of purchase, Atwood will repair or replace any part | exclusion or limitation of incidental or consequential damages, so the above |
| defective in material or workmanship. This warranty includes reasonable labor | limitations or exclusions may not apply to you. |
| charges, required to remove and replace the part. Service calls to customer’s | 10. Any implied warranties are limited to two (2) years. Some states do not allow |
| location are not considered part of these charges and are, therefore, the | limitations on how long an implied warranty lasts, so the above limitation may |
| responsibility of the owner. | not apply to you. This warranty gives you specific legal rights and you may |
3. | This warranty does not cover the following items classified as normal maintenance: | also have other rights which vary from state to state. |
| a. adjustment of | 11. Replacement parts (components or tanks) purchased outside of the original |
4. | In the event of a warranty claim, the owner must contact, in advance, | water heater warranty carry a 90 day warranty. This includes the part at no |
| either an authorized Atwood Service Center or the Atwood Service | charge and reasonable labor charges to replace it. |
| Department. Warranty claim service must be performed at an authorized | This Atwood heater is designed for use in recreational vehicles for the purpose of |
| Atwood Service Center (a list will be provided at no charge) or as | heating water as stated in the “data plate” attached to the water heater. Any other |
| approved by the Consumer Service Department, Atwood Mobile Products, | use, unless authorized in writing by the Atwood Engineering Department, voids this |
| 1120 North Main St., Elkhart, IN 46514 USA. Phone: | warranty. |
SAFETY INFORMATION
FOR YOUR SAFETY
READ ALL INSTRUCTIONS BEFORE OPERATING APPLIANCE
REFER TO THE RATING PLATE FOR M0DEL NUMBER
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards. Obey all safety messages following these symbols.
WARNING | CAUTION |
avoid possible | avoid possible |
injury or death | injury and/or property damage |
Installer: Provide these instructions to the consumer.
Consumer: Keep documents for future reference.
WARNING
FIRE
• Do not smoke or have any flame near an open faucet.
If you have not used this water heater for more than two weeks, hydrogen gas may result. Under these conditions to reduce the risk of injury, open the hot water faucet for several minutes at the kitchen sink before you use any electrical appliance connected to hot water system.
If hydrogen is present, you will probably hear sounds like air escaping through the pipe as water begins to flow. Allow the water to flow until these sounds disappear.
6.Bleed air from the entire coolant system for proper operation of both engine and water heater.
7.Connect electric supply at junction box (FIG
NOTE: For marine installation, use conductors as specified by sub chapter S, part 183.425, table 5 of chapter 1 - Coast Guard Department of Transportation Code of Federal Regulations Title 33.
8.To ground water heater, connect grounding wire from electrical service to the green wire.
WARNING
EXPLOSION
MARINE INSTALLATION ONLY
•Locate switch in an area where ignition protection is not required.
9.EHM6, EHM11,
Use UL LISTED ON/OFF switch rated for 15 amps/125V AC.
EHM6-220, EHM11-220, E20-220 and EH20-220:
Use UL LISTED ON/OFF switch rated for 10
10.Fill the heater with water. Open the hot water faucet connected to the heater until all air is gone.
11.EHM6, EHM11,
Connect to
Connect to a
12.Thermostat is factory set and is not adjustable.
13.Replace cover.
GARANTIE LIMITÉE POUR
INSTALLATION
1. Position water heater on plywood floor (5/8˝ minimum). Locate at or |
CAUTION
PRODUCT DAMAGE
Atwood Mobile Products garantit ce produit à l'acheteur initial, suivant les termes stipulés
La responsabilité d'Atwood décrite
1.Pendant une période de deux ans, à compter de la date d'achat, Atwood remplacera tout le
2.Pendant deux ans, à compter de la date d'achat, Atwood réparera ou remplacera toute pièce trouvée défectueuse en raison du matériau ou d'un vice de fabrication. La présente garantie couvre les frais raisonnables de
3.La présente garantie ne couvre pas les articles suivants, qui sont considérés comme faisant partie de l’entretien régulier :
a. réglage de la soupape de décharge de type
4.Dans l'éventualité d'une réclamation de garantie, l’acheteur doit contacter, à l'avance, soit un centre de service Atwood agréé, soit le Service à la clientèle Atwood. La réclamation de garantie doit être exécutée dans un centre de service Atwood agréé (une liste vous sera fournie gratuitement) ou selon les procédures reconnues par le Service clientèle Atwood (Consumer Service Department) Atwood Mobile Products, 1120 North Main St., Elkhart IN 46514
5.Les pièces retournées (ou le
d’Atwood Mobile Products et doivent être retournées à Consumer Service Department, Atwood Mobile Products, 6320 Kelly Willis Road, Greenbrier, TN 37073
6.La présente garantie est valide uniquement si l'unité est installée selon les consignes d'installation fournies, en conformité avec les codes locaux et nationaux.
7.La période de garantie pour les pièces de remplacement (ou le
8.Tout dommage ou toute déficience résultant d'une mauvaise utilisation (y compris le manquement à faire effectuer les réparations nécessaires), d'une mauvaise mise en application, de modifications, de dommages causés par l'eau ou par le gel relèvent de la responsabilité de l’acheteur.
9.Atwood n’est aucunement responsable de l’impossibilité d’utiliser le véhicule, de toute perte de temps, de tout dérangement et de tous frais d'essence, de téléphone, de déplacement, de logement, de perte ou de dommages aux biens personnels ou de perte de revenus. Certains États ne permettent pas l’exclusion ou la limitation des dommages accessoires ou indirects ; il est donc possible que les limitations ou exclusions
10.Toute garantie implicite est limitée à une période de deux (2) ans. Certains États ne permettent pas de limiter la période d'une garantie implicite, donc il est possible que la limite
11.Les pièces de remplacement (composantes ou réservoirs) achetées en dehors de la garantie initiale du
Ce
below engine level. |
2. MODELS EHM4 & EHM6: |
Secure to flooring with eight No. 12 x 3/4˝ wood screws through the front and rear
MODELS EHP10, EHM11, E20, & EH20:
Secure to flooring with eight
3.Connect both 1/2˝ NPT water lines (FIG
4.Fill water heater tank and check all connections for water leaks (FIG
5.Connect 5/8˝ diameter SAE 20R3 or equivalent coolant hose to heat exchange tubes at rear or front of water heater (FIG
FOR COOLANT LINE CIRCUIT:
Push hose end (with clamp attached) onto tube as far as possible. Spread hose clamp, slide it past annular groove and release (FIG 3 A,B,C,D).
EHP-10 MODEL WATER HEATER INSTALLATION: FIG 4
Install the normally closed vacuum valve
WARNING
SCALDING INJURY
EHP-10 MODEL WATER HEATER:
• Install only the specified temperature control system.
• Do not operate without water in tank
14.Turn remote switch to ON. Your water heater is now operating. NOTE: This water heater is equipped with temperature & pressure relief
valve that complies with the standard for Relief Valves & Automatic Gas Shutoff Devices for Hot Water Systems, ANSI Z21.22. (FIG 2).
NOTE: Allow for complete drainage of both valve and discharge line.
WARNING
SCALDING
•Pressure temperature relief valve is not serviceable, it must be replaced.
•Tampering with valve will result in scalding injury.
•Tampering with valve will void warranty.
WARNING
EXPLOSION
•Do not place a valve, plug or reducing coupling on outlet port of pressure temperature relief valve or block the discharge opening.
•If you use a discharge line, do not use a reducing coupling or other restriction that is smaller than the outlet of the relief valve.
•Install temperature and pressure equipment, required by local codes, to protect against excessive pressures and temperatures.
•The Combination Temperature and Pressure relief valve must be installed into the water heater coupling provided and marked.
•Orient the valve or provide tubing so that any discharge from the valve will exit only within 6 inches above, or at any distance below the structural floor and cannot contact any live electrical part.
8 | 1 |