3. Operation
NOTE: The CT240 will automatically hang up if no key is pressed during the 30 seconds following the CT240 answering a call.
Default values:
•Access code = 1234
•Number of rings = 4
3.1 With or Without an Answering Machine
B EG I N A S ES S I O N (wi th o u t a n s we ri n g m a c h i n e)
Dial your phone number
Wait for the number of rings...
CT240 answers
B EG I N A S ES S I O N (wi th a n an s we ri n g m ac h i n e )
Dial your phone number
Let it ring once and hang up
Wait 10 seconds...
Dial your phone number again within the next 30 seconds
CT240 answers (1st ring)
EN TER YO U R AC C E S S C O D E
Enter your | Accepted |
| |
(default: 1234) | Error |
|
O U TP U T S TATU S /M O D I F Y S TATU S
Press | for output status | Comfort |
Press | to change status | Vacation |
M O D I FY TH E AC C E S S C O D E
Press
Enter your new
Accepted
Enter the access code again
Error
M O D I FY TH E N U M B E R O F RI N G S
Press |
| |
|
| |
Enter the number of rings after | x the number of | |
which the CT240 will answer | ||
selected rings | ||
(between 1 and 9) | ||
| ||
|
| |
EN D S E S S I O N |
Press to end the session
3.2 Manual Output Activation Button
The button, located on the
The light is ON when the auxiliary output is in Vacation mode (termi- nals 1 and 2 closed)
3.3 Reset to default values
Insert a pointed object (e.g. paper clip) in the hole located under the Reset light. The light will flash 3 times to indicate that the CT240 has been reset:
• number of rings: 4
• access code: 1234
•Output status:
ABC: Terminals A and C: Comfort
123: Terminals 1 and 2: opened, Terminals 2 and 3: closed
4. Technical Speci fi cations
Power supply: 9 VAC / 60 Hz (50 Hz Europe)
Output (ABC): 0 VDC = Comfort mode / 12 VDC = Vacation mode
Maximum load for parallel connection of Aube thermostats: 50 mA
Auxiliary output (123): SPDT with following capacity:
•5 A / 30 VAC inductive / Power Factor: 0.4
•10 A / 30 VAC resistive (if installed in a certified electrical box)
•10 A / 240 VAC resistive (if installed in a certified electrical box)
•1/2 HP / 120 VAC motor (if installed in a certified electrical box)
•1 HP / 240 VAC motor (if installed in a certified electrical box) Protection: Class II
Access code (default): 1234
Number of rings (default): 4 rings
Memory protection: In case of power failure, access code and out- put status are protected.
Phone certification standard:
•FDTBR21: European telephone network
•FCC68: North American telephone network Approvals:
•c UL us (North America)
•CE (Europe)
Dimensions (H W D): 2.7 x 5.4 x 1.2 in. (69 x 137 x 31 mm)
5. Warranty
AUBE TECHNOLOGIES INC. THREE (3) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a three- year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and with- out charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufac- turer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the nearest shipping address.
705 Montrichard | 10 | Ampère Street |
95500 Gonesse | ||
Quebec, Canada J2X 5K8 | France | |
Tel.: (450) | 33 | (0) 1 34 07 99 00 |
Toll Free: |
|
|
Fax: (450) | 33 | (0) 1 34 07 99 19 |
service@aubetech.com | advaube@comintes.com |
For more information on our products,
visit us at www.aubetech.com
29/10/2003 | 2/2 |