Aube Technologies TH101A manual Programming, Adjustment of time and day, Typical proposed programs

Models: TH101A

1 4
Download 4 pages 54.94 Kb
Page 2
Image 2
PROGRAMMING

PROGRAMMING

ATTENTION : The thermostat cannot be programmed if it is not connected on the 120/240 VAC line.

1) Adjustment of time and day

Example of setting : Thursday 8:15 AM

Press once on HOUR key to enter time and day setting.

Press HOUR key a second time and hold it until 8:00 appears on the display.

Press and hold MIN key until 8:15 appears on display.

Press 3 times on DAY key until TH appears on display.

Press RET to exit the time and day adjustement mode.

Note: The thermostat has an automatic return. When such functions as time recording, programs recording, etc., are not completed by pressing RET key, the thermostat will automatically exit the mode.

2) Typical proposed programs

This thermostat can store up to six (6) programs. Four (4) programs for the weekdays and two (2) programs for the weekend.

To practice programming use the following example.

WEEKDAY PROGRAMS (MON...FRIDAY)

PROGRAM

STARTING

TEMPERATURE

NUMBER

TIME

SETTING

 

 

 

Program 1

6:00 AM

20 °C

 

 

 

Program 2

8:30 AM

15 °C

 

 

 

Program 3

4:30 PM

20 °C

 

 

 

Program 4

11:00 PM

15 °C

 

 

WEEKEND PROGRAMS (SAT & SUN)

 

 

 

 

Program 1

7:00 AM

20 °C

 

 

 

Program 2

11:00 PM

15 °C

 

 

 

3) Program ming the thermostat

Press PGM key once.

The default values or the last recorded program 1 will be displayed.

The default values are 20 °C and 0:00 hour.

The days MOnday to FRiday are displayed showing that this program is associated to weekdays.

Press HOUR key until 6:00 AM is displayed.

Press t or s button until 20 °C is displayed.

The first program is recorded.

Press PGM key again to modify weekday programs 2, 3, 4, and weekend programs 1 and 2.

Use HOUR, MIN, t or s key to modify programs time and setpoint.

Note: A program time left at 0:00 is considered not effective.

To reset a program, use PGM key to select the program, than press MODE button.

Programming is now completed. Press RET key or wait for "automatic return" to exit the programming mode.

4) Programming the Stanby mode temperature

The STBY ( STANDBY ) temperature is the desired temperature setting for a prolonged absence.

Press MODE button while PGM key is pressed in. Display shows Ad (SW1=Off) or OP (SW1=On).

Attention : Do not modify Op setting (Op=5).

Press PGM key until display shows Sd and default value 10°C or the last recorded one.

Select the desired temperature with t or s button. ( ex: 12 °C ).

Press RET key to exit from programming the STBY mode temperature.

Page 2
Image 2
Aube Technologies TH101A Programming, Adjustment of time and day, Typical proposed programs, Program ming the thermostat