OPERATION
Operation modes
The thermostat has four (4) operation modes :
AUTO, MAN, STBY AND OFF.
They are selected through the MODE button. On display, the active mode is framed. The frame moves on to the next mode each time the MODE button is pressed.
NOTES :
When scrolling from the operation mode OFF to an active mode, the thermostat will take 5 to 10 seconds to display the room temperature.
In normal use, the thermostat housing temperature can reach 35 °C to 45 °C.
AUTO | The | AUTOmatic | mode | |
executes in sequence (hourly) | ||||
| ||||
| ||||
| the programs recorded by the | |||
| user. |
|
|
Pressing on the t or s button displays the temperature setting for five (5)econds.
MAN | The MAN | operation | mode |
| allows the user to bypass the | ||
| programming | and holds | the |
| present temperature. |
|
The first time the t or s button is pressed, the temperature setting is displayed. For all subsequent times pressed, the temperature setting will change 1°C.
STBY
| The STBY ( STANDBY) mode | |
| allows an immediate adjustment | |
| of the temperature setting. It is | |
| factory set to 10 °C. User can | |
| modify by refering to section: | |
| PROGRAMMING | TH E STBY |
| MODE TEMPERATURE. | |
| A pressure on the t or s button | |
| displays the | temperature |
| setting for five (5) seconds. | |
| Why should you use the STBY | |
OFF | mode? |
|
|
| |
|
|
|
If you leave your home for the weekend and you wish to keep the temperature to an economic level, instead of adjusting the thermostat in manual mode and changing the setpoint of all units, just set the thermostat in STBY mode.
In this mode, the electric heating system is turned off. Only the time and the operation OFF mode framed are displayed.
CHARACTERISTICS
1) Proportional control
This thermostat works differently than the conventional
The proportional controller determines the amount of power required by the electric heating system to maintain the exact ambient temperature of the temperature setting.
The display shows, in real time, the applied power to the electric heating system.
If you have set the switch #1 at position «ON » to control a fan equipped system, the display will show 100 % when the heating system is turning on and 0 % when it is OFF. In that case, the temperature regulation is +/ - 0.5°C around the set point.
2) Characteristics
-Model: TH101A
-Electronic Programmable line voltage thermostat (2 wires).
-Supply: 120/240 VAC, 50/60 Hz.
-Load: 16.6 Amp. maximum, 1.8 Amp minimum (Resistive only).
-Power: 4000 W / 240 VAC or 2000 W / 120 VAC.
-Power consumption (off) : 860mW.
-Approvals: CSA
-Display range: 0 to 40 °C (32 to 99 °F)
-Setting range: 5 to 35 °C (41 to 95 °F)
-Storage:
-Temperature control: 0.3 °C (SW1=Off), +/- 0.5 °C (SW1=On).
-Precision: ± 0.5°C (2500W), 0.9°C (4000W) of temperature setting.
-Six (6) programs: 4 weekday programs and 2 weekend programs.
WARRANTY
AUBE TECHNOLOGIES INC. LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage.
This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE Technologies inc. be liable for consequential or incidental damages resulting from installation of the thermostat. Within this period, any thermostat proven defective in normal use will be repaired or replaced, at AUBE's option, without charge for either parts or labor, provided that the thermostat with the original sale receipt is returned to the original dealer or is shipped
AUBE Technologies inc.
Services centre