2) Options selection

2) Options selection

Some options have been factory set. Those default settings are:

The temperature is in °C, the heating control is propotional and the time format is 24 hours.

2.1 Temperature displayed in °C or °F

To change the temperature from °C to °F and back, maintain DAY button pressed down as RESET button is being pressed on and released. Then release DAY button.

2.2 Time format displayed in 24 hours or 12 hours

To change the time format from 24 hours to 12 hours and back, maintain HOUR button pressed down as RESET button is being pressed on and released. Then release HOUR button.

2.3 Proportional or ON/OFF heating control

This thermostat has been factory set to proportionally control electric baseboards, radiant systems and convectors. Since proportional control uses a fast commutation rate, it is not compatible with fan equipped systems (see characteristics). Also, this control mode could occasionally create light flickering, especially in rural area.

You can change the control mode to make it compatible with fan equipped systems or to eliminate the light flickering.

ECONO

The ECONO mode has two (2) programs in which the day, the time and the setpoint has to be programmed. For instance, this operating mode can be used for a cottage installation where the user goes only on weekends.

Program 1: Friday 3:00 PM, 21 °C

Program 2: Friday 8:00 PM, 15 °C

The temperature will be maintained at 21 °C Friday from 3:00 PM to 8:00 PM, and maintained at 15 °C the rest of the week.

This gives you a comfortable temperature at your arrival and if you are not going to your cottage for the weekend, there will be only a minimal heating period.

To see the ECONO programs, select the ECONO operating mode and press on PGM button successively to see programs 1 and 2 appear on the display show the temperature setting. All subsequent pressures will over- ride your programming up to the next program.

To do so, maintain MIN button pressed down as RESET button is being pressed on and released. Then release MIN button. Following this operation, the display will show the fan indicator. To return to proportional control, repeat the same operation.

3) Memory backup

In the event of a power failure, an internal circuit will maintain the programming. The display will stay on for 15 minutes; beyond this period, the display will turn off. An indicator "LP" will be shown on the display. Only the time will have to be set if power failure is more than six hours. The thermostat will return to the same operation mode as set before the power failure.

4) First power-up

When power is applied for the first time, the display must show the day and hour as follows:

0:00 MO (Monday)

The active operation mode is the framed MAN mode, the temperature setpoint is 20 °C and the ambiant temperature is displayed.

If the display is different, maintain PGM button pressed down as RESET button is being pressed and released. Then release PGM button.

500 WATTS OR LESS INSTALLATION

During the 30 minute period following the installation or a long power failure (more than 6 hours), the light intensity of the display decreases when a button is pressed on while the thermostat is in the heat mode. This problem will disappear when the accumulator for the memory backup will be charged.

OPERATING MODES

PROGRAMMING

1) Adjustment of time and day

Example of setting: Thursday 8:15 AM

Use DAY, HOUR and MIN buttons to set the time.

Once set, press on RET button to exit the time and day adjustment mode

Note 1 : Time indicator is showing you that the time must be set.

Note 2 : The thermostat has an automatic return. When such functions as time recording, programs recording, etc., are not completed by pressing on RET button, the thermostat will automatically exit the mode after 60 seconds.

2) Typical suggested programs

This thermostat can store up to four (4) daily programs for weekdays and four (4) daily programs for the weekend. Also, there is two (2) programs for the ECONO mode. To practice programming use the following example.

AUTO

MAN

The TH101D thermostat has three (3) operating modes:

AUTO, MAN and ECONO.

They are selected through the MODE button. On display, the active mode is framed. The frame moves on to the next mode each time the MODE button is pressed on.

The AUTOmatic mode runs in sequence (hourly) the programs recorded by the user.

By pressing once ECONOor 3) Memory backup displays shows the tempera- ture setting. All subsequent pressures will override your programming up to the next program.

To see the weekday and weekend programs, select the AUTO mode and press successively on PGM button to see the programs appear on the display.

The MAN mode allows the user to override the programming.

The first time the 4) First power-up or OPERATING MODES is pressed on, the tempera- ture setting is displayed. For all subsequent times pressed on, the temperature setting will change 1 °C.

Program number

Time

Temperature setting

 

 

 

 

Weekday programs (Mon...Friday)

 

 

 

Program 1

6:30 AM

20

°C

 

 

 

 

 

Program 2

8:30 AM

15

°C

Program 3

4:30 PM

20

°C

 

 

 

 

 

Program 4

11:00 PM

15

°C

 

 

 

 

Weekend programs (Sat & Sun)

 

 

 

Program 1

7:00 AM

20

°C

 

 

 

 

 

Program 2

8:30 AM

15

°C

Program 3

4:30 PM

20

°C

 

 

 

 

 

Program 4

11:00 PM

15

°C

ECONO mode programs (weekend cottage)

 

 

 

Program 1

Friday 3:00 PM

21

°C

Program 2

Friday 8:00 PM

15

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

720-101002-A