7. Operation
7.1 Backlight
When either of the buttons is pressed, the display is lit for 10 seconds. The setpoint appears for 5 seconds, then the actual tem- perature is displayed.
When the backlight button is pressed, the display is lit for 5 sec- onds. NOTE: If the thermostat is mounted on a
7.2 Displaying and Setting the Temperature
The thermostat normally displays the actual temperature. To view
the setpoint, press once on one of the buttons. The setpoint is displayed for 5 seconds. During the setpoint display, press one of
the buttons to change it. To scroll the setpoint faster, press and hold the button.
7.3 Setting the Floor Temperature Limits (AF model only)
The thermostat generally turns heating On or Off to con- trol the ambient temperature. However, if the floor tem- perature drops below the set minimum floor temperature limit or rises above the maximum limit, the thermostat will turn heating On or Off respectively, regardless of the ambient temperature, to maintain the floor temperature within the desired limits.
The minimum and maximum floor temperature limits are
nSwitch the thermostat to Standby.
oWhile pressing any button, switch the thermostat back to On to access the floor temperature limit settings.
pPress the Test button briefly to switch between minimum and maximum floor temperature settings.
qPress the buttons to set the desired limit.
rPress the Test button for 3 seconds to save your modifications. After the data are saved, the thermostat displays the actual ambient temperature or “–
Note: Your modifications are also saved if no button is pressed for 60 seconds.
sSwitch the thermostat to Standby and back to On to reset the
GFCI and return to the normal display.
:
8. Techn ical Specifications
Power supply: Refer to the power base installation instructions.
Ambient setpoint range (A/AF models): 5°C to 30°C (40°F - 86°F)
Floor limit range (AF model): 5°C to 40°C (40°F - 104°F)
Floor setpoint range (F model): 5°C to 40°C (40°F - 104°F)
Setpoint resolution: ± 0.5°C (1.0°F)
Display resolution: ± 0.5°C (1.0°F)
Duty cycle: Refer to the power base installation instructions.
Storage:
9. Warranty
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installa- tion. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commit- ment.
AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address.
1 0. Service
705 Montrichard
J2X 5K8
Canada
T: (450)
F:(450)
For more information on our products, visit us at:
www.aubetech.com
TH114 | 21/2/05 | 2/2 |