TH1 1 4
1 . Description
Aube’s TH114 Series
A model: | controls and displays the ambient temperature | |
|
|
|
F model: | controls and displays the floor temperature | |
|
| uses an external temperature sensor |
|
|
|
AF model: | controls and displays the ambient temperature | |
|
| maintains the floor temperature within desired |
| limits | |
|
| uses an external temperature sensor |
User s Guide
Non-programmable Thermostat
3. I nstallation
nRefer to the installation instructions of the
power base.
o Insert the tabs at the top of the control module in the slots at the top of the power base.
p Secure the control module using the cap- tive screw underneath the base.
Note: Do not obstruct the thermostat's vents.4. Power-up
As soon as the thermostat is powered, it undergoes a series of tests before displaying the actual tempera- ture.
GFCI fault light *
Arrow appears when the setpoint is displayed
Power output
1 to 24%
25 to 49%
50 to 74%
75 to 99%
100%
* available on certain models only
Actual or setpoint temperature
GFCI fault indicator *
Temperature adjustment button
GFCI test button * /
Backlight button *
On/Standby button
5. Error Messages
The measured temperature is below 0°C (32°F). Heat- ing is turned On.
The measured temperature is above 50°C (122°F) (A or AF model) or 60°C (140°F) (F model).
The floor sensor is defective or not properly connected (F model only), or the thermostat is defective.
6. GFCI Test
Each thermostat consists of a control module which must be mounted on a PB112 Series power base. For the selection and installation of the power base, refer to its installation instructions.
2. DI P Switch Configuration
The DIP switches are located at the back of the control module.
2.1 Temperature Display (S1 )
To switch between °C and °F.
2.2 Model (S2)
Note: Available on certain models onlyF: To select the F model
AF: To select the A or AF model
Note: This procedure must be performed if the thermostat is mounted on a
Test the GFCI immediately after installing the control module, and once a month there- after.
n Raise the temperature | until the heat- |
ing power indicator | appears. |
o Press the Test button. |
|
p If the test is successful, you will hear a click caused by the GFCI relay tripping. The heating power indicator will disap- pear, GFI will appear and the Fault light will illuminate. Reset the thermostat by switching it to Standby and back to On.
qIf the test has failed, cut power to the heating system from the main electrical panel and call customer service.
Note: If the Fault light is On during normal operation, cut power to heating system at the main electrical panel and have an electrician verify the installation.
TH114 | 21/2/05 | 1/2 |