1 . Description

Aube’s TH114 Series non-programmable thermostats can be used to control ambient or floor temperature. The following models are available:

A model:

controls and displays the ambient temperature

 

 

 

F model:

controls and displays the floor temperature

 

 

uses an external temperature sensor

 

 

 

AF model:

controls and displays the ambient temperature

 

 

maintains the floor temperature within desired

 

￿

limits

 

 

uses an external temperature sensor

User￿ s Guide

Non-programmable Thermostat

3. I nstallation

nRefer to the installation instructions of the

power base.

o Insert the tabs at the top of the control module in the slots at the top of the power base.

p Secure the control module using the cap- tive screw underneath the base.

Note: Do not obstruct the thermostat's vents.

4. Power-up

As soon as the thermostat is powered, it undergoes a series of tests before displaying the actual tempera- ture.

GFCI fault light *

Arrow appears when the setpoint 1 . Description is displayed

Power output

1 to 24%

25 to 49%

50 to 74%

75 to 99%

100%

* available on certain models only

Actual or setpoint temperature

GFCI fault indicator *

User￿ s Guide Temperature adjustment button

GFCI test button * /

Backlight button *

On/Standby button

5. Error Messages

The measured temperature is below 0°C (32°F). Heat- ing is turned On.

The measured temperature is above 50°C (122°F) (A or AF model) or 60°C (140°F) (F model).

The floor sensor is defective or not properly connected (F model only), or the thermostat is defective.

6. GFCI Test

Each thermostat consists of a control module which must be mounted on a PB112 Series power base. For the selection and installation of the power base, refer to its installation instructions.

2. DI P Switch Configuration

The DIP switches are located at the back of the control module.

2.1 Temperature Display (S1 )

To switch between °C and °F.

2.2 Model (S2)

Note: Available on certain models only

F: To select the F model

AF: To select the A or AF model

Note: This procedure must be performed if the thermostat is mounted on a GFCI-equipped power base.

Test the GFCI immediately after installing the control module, and once a month there- after.

n Raise the temperature

until the heat-

ing power indicator

appears.

o Press the Test button.

 

p If the test is successful, you will hear a click caused by the GFCI relay tripping. The heating power indicator will disap- pear, GFI will appear and the Fault light will illuminate. Reset the thermostat by switching it to Standby and back to On.

qIf the test has failed, cut power to the heating system from the main electrical panel and call customer service.

Note: If the Fault light is On during normal operation, cut power to heating system at the main electrical panel and have an electrician verify the installation.

TH114

400-114-000-B

21/2/05

1/2

Page 1
Image 1
Aube Technologies TH114 installation instructions Description, I nstallation, Power-up, Error Messages, GFCI Test, TH1 1