3.3 Master Thermostat - Installation and Wiring
WARNING: Make sure all slave units are in STANDBY mode.
•Required parts:
• Location: anywhere easily accessible to users.
Temperature control: AF (ambient with floor limit) / A (ambient)
•Install the master thermostat in the controlled area.
•Choose a location about 5 ft. above the floor in an area where the tempera- ture is stable.
•Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
Temperature control: F (floor)
•Can be installed anywhere.
sWire the 12 VDC base to the nearest slave unit.
The floor sensor must be installed in an area where average temperature can be read. The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire.
For maximum performance, the sensor probe should be centered between the wires in the mat (max. 80°C).
tPush the excess wire into the wall, secure the base using the provided screws and wall anchors, and install the TH11x thermostat onto the base.
uOnce the thermostat is installed, return power to heating system and switch all slave units and the master thermostat to ON.
3.4 Slave Units - GFCI Test
We recommend you test the GFCI immediately after installing the thermostat, and once a month thereafter to ensure it is operating properly.
If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and verify the installation.
nSlide the protective door upwards and make sure the switch is ON. o Press TEST.
•The test is successful if the TEST warning light is ON and power is cut off.
•If the test fails (first installation test):
a.Verify installation
b.Check the load wires
c.Once you've identified the problem, run the GFCI test again
•If the test fails (monthly maintenance):
a.Cut power to heating system from the main power panel and call customer service
pWhen the test is successful, reset the slave unit by switching from ON to STANDBY then back to ON.
qRepeat steps 1 to 3 for all slave units.
Technical Specifications
Temperature:
-Operation: 32°F to 122°F (0°C to 50°C)
-Storage:
TH113/TH114/TH115/TH116 (A/F/AF-12VDC)
Power supply | 12 V from remote unit |
|
|
Maximum | up to 10 slave units per |
slave units | master thermostat |
|
|
Wire gauge | 20 AWG |
|
|
Size (H • W • D) | 4.63 x 2.7 x 0.61 in. |
BASE | (117.5 x 68.3 x 15 mm) |
CT230-120GA/120GB/240GA/240GB
Supply |
|
- | 1800 W @ 120 VAC |
| 60 Hz, 15 A resistive |
- | 3600 W @ 240 VAC |
| 60 Hz, 15 A resistive |
|
|
GFCI | GA=5 mA / GB=30 mA |
|
|
Certification | c CSA us |
|
|
Size (H • W • D) | 4.63 x 2.7 x 1.45 in. |
BASE | (117.5 x 68.3 x 37 mm) |
|
|
Size (H • W • D) | 4.67 x 2.74 x 0.67 in. |
INTERFACE | (118.6 x 69.6 x 17 mm) |
Service
If you have any questions concerning the installation of the master thermostat or slave units, contact our technical support team at:
Montreal area: | (450) |
Canada / U.S.: | |
Fax: | (450) |
Email: | service@aubetech.com |
Monday to Friday from 8:30 AM to 5:00 PM EST.
For more information on our products, visit us at www.aubetech.com
Warranty
AUBE TECHNOLOGIES INC.
ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment.
AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:
Aube Technologies Inc.
705 Montrichard
Canada J2X 5K8